Dear Customer: 
 
Congratulations!  Compliance West USA is proud to present you with 
your  new  Tester.    Your  instrument  features  a  groundbreaking  circuit 
design  and  ergonomic  front  panel  and  represents  the  latest  in  high 
current production line testing. 
 
To fully appreciate all the features of your new meter, we suggest that 
you  take  a  few  moments  to  review  this  manual.    Compliance  West 
USA  stands  by  your  instrument  with  a  full  one-year  warranty.    If  the 
need arises, please don't hesitate to call on us. 
 
Thank you for your trust and confidence. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Rev.3. 0, May 2012. 

 

Summary of Contents for GFM-200A

Page 1: ...GFM 200A Instruction Manual...

Page 2: ...nel and represents the latest in high current production line testing To fully appreciate all the features of your new meter we suggest that you take a few moments to review this manual Compliance Wes...

Page 3: ...Fuse Replacement 3 Front Panel Features 4 Front Panel Description 4 Rear Panel Features 5 Rear Panel Description 5 Initial Checkout Procedure 6 Operating Techniques 6 Technical Assistance 7 Maintenan...

Page 4: ...1...

Page 5: ...s warranted for a period of one year upon shipment of the instrument to the original purchaser Specifications Specifications for the GFM 200A are listed in Table 1 1 GFM 200A Specifications ELECTRICAL...

Page 6: ...ailable be sure that adequate protection is provided to prevent damage during shipment We recommend that the instrument be surrounded by at least one inch of shock absorbing material on all sides of t...

Page 7: ...TEM NO NAME FUNCTION 1 Variac Knob The Variac knob increase or decrease the current outpu of the GFM 200 Before operating the tester turn down the knob to the minimum 2 ON OFF Switch The ON OFF Switch...

Page 8: ...ied cordset to connect the GFM 200A tester to an appropriate source of supply 2 Fuse Fuse holder provides access for Fuse replacement 3 Output Tester Output is located in the back use the cable attach...

Page 9: ...h 9 Short circuit the output leads and connect a current clamp meter at one of the leads 10 Turn the power switch to the I or ON position 11 Increase the current by turning the variac knob clockwise a...

Page 10: ...rom Compliance West USA is available Phone 800 748 6224 Hours 8 30 AM 4 30 PM Pacific Time Also available on our web site at www compwest com Contact Compliance West USA 650 Gateway Center Way Suite D...

Page 11: ...t no charge Mail the instrument post paid to the manufacturer Dated proof of purchase is required for all in warranty repairs The manufacturer is also available for calibration and or repair of instru...

Page 12: ...has been repaired The calibration procedure should be performed at an ambient temperature of 23 C 5 C 73 4 F 9 F The procedure consists in the verification and calibration of the meter reading The Cal...