background image

2

 

WARNING

To ensure proper bed rail installation, arrows on crossbrace decal MUST point to 

center of bed.
The outer telescoping tube of the bed rail MUST be positioned at the head end of 

the bed to prevent a pinch point when raising/lowering bed. 
To reduce the risk of entrapment make certain that the crossbraces DO NOT 

exceed the width of the mattress. Mattress MUST fit bed frame and side bed rails 

snugly to reduce the risk of entrapment. 
Unless the bed rail is in the lowest position, ensure that the spring loaded knobs fully 

protrude through the same respective adjustment hole of each bed rail tube. This 

ensures that the bed rail is securely locked in position and an even height 

adjustment is achieved (The lowest position for the bed rail occurs when the bed rail 

rests against the bed rail stop. Spring loaded pins DO NOT engage into an 

adjustment hole when the bed rail in the lowest position.)
Install bed rails fully extended on bed. DO NOT use full length bed rails as half rails.

Installing the Crossbraces

NOTE: READ AND UNDERSTAND WARNINGS before proceeding with Installing the 

Crossbraces on page 2.
NOTE: For this procedure, refer to FIGURE 1 on page 3.

1. Remove the mattress from the bed.
2. Place the bed in the flat position and position one crossbrace between the sixth and 

seventh springs at the head end of the bed frame (Detail “A”).

NOTE: If the bed frame contains BLACK springs at the sixth and seventh spring locations at the 

head end of the bed, position the crossbrace between these springs.

3. When holding either end of the crossbrace assembly, turn the barrels so plunger knobs 

are on top (Detail “A”).

NOTE: Ensure the long end of the barrel faces the center of the bed with the decal to the center of 

bed as shown in FIGURE 1. If long end faces the opposite way, rotate crossbrace 180°.

4. Position the bed hooks so they are on the bottom side of the crossbrace (Detail “B”).
5. Perform one of the following:

• Standard Hardware Installation - Attach one bed hook onto the bed spring angle 

iron and push in on the spring loaded bed rail until you are able to attach the 

opposite end to the bed spring angle iron (Detail “B”).

NOTE: Ensure plunger pins are facing the center of the bed.

• Optional Hardware Installation - Perform the following steps:

i. Attach wingnuts to bed hooks.
ii. Tighten until the wingnut reaches the bed spring angle iron.

Summary of Contents for PB6034

Page 1: ...d rail dimensions and mattress thickness size or density could increase the risk of entrapment Visit the FDA website at http www fda gov to learn about the risks of entrapment Compass products are spe...

Page 2: ...ing with Installing the Crossbraces on page 2 NOTE For this procedure refer to FIGURE 1 on page 3 1 Remove the mattress from the bed 2 Place the bed in the flat position and position one crossbrace be...

Page 3: ...be positioned at the head end of the bed to prevent a pinch point when raising lowering bed NOTE READ AND UNDERSTAND WARNINGS before proceeding with Installing the Bed Rails NOTE For this procedure re...

Page 4: ...on unless the bed rail is at the lowest position NOTE The lowest position for the bed rail is when the bed rail rests against the bed rail stop Spring loaded pins DO NOT have an adjustment hole to eng...

Page 5: ...rialized indicate the serial number Do notreturnproductsto our factorywithoutour priorconsent LIMITATIONSAND EXCLUSIONS THE FOREGOINGWARRANTY SHALLNOTAPPLY TO SERIAL NUMBEREDPRODUCTSIFTHE SERIAL NUMBE...

Page 6: ...ance et l valuation appropri es du patient et la maintenance et l utilisation appropri es de l quipement doivent tre mises en uvre pour limiter le risque de pi geage Les variations de dimensions des c...

Page 7: ...nn entre les sixi me et septi me ressorts en t te de lit Le croisillon restant DOIT tre positionn entre les deuxi me et troisi me ressorts en pied de lit Sinon le c t de lit ou le lit risque d tre end...

Page 8: ...e et troisi me ressorts en pied de lit REMARQUE Si les ressorts des deuxi me et troisi me positions c t pied du CADRE DE LIT sont NOIRS placer le croisillon entre ces ressorts 8 R p ter les TAPES 3 7...

Page 9: ...tube t lescopique int rieur du c t de lit dans le cylindre du croisillon en pied de lit 7 R p ter les TAPES 3 5 pour le tube t lescopique int rieur du c t de lit en r glant celui ci sur la position at...

Page 10: ...ente vers le centre du lit Bouton de tige Le coincement du patient d ans l espace entre les c t sdelit peut causer des blessures oula mort Le matelas doit tre ajust au cadre etaux c t s du lit afin d...

Page 11: ...duitsi celui ci estnum rot ens rie Ne pas retournerdeproduit notreusine sans aurtorisationpr alable LIMITATIONSET EXCLUSIONS LAGARANTIE QUI PR C DE NE S APPLIQUERA PASAUX PRODUITSNUM ROT SEN S RIE SIL...

Page 12: ...800 668 5324 All rights reserved Trademarks are identified by the symbols and All trademarks are owned by or licensed to Invacare Corporation unless otherwise noted 2007 Invacare Corporation Part No...

Reviews: