4
Location Of
Terminals
GTAW Connections
SMAW Connections
Figure 3-5 Weld Output Connections.
Gas Or Water
Hose
1
2
OR
3-4 CONNECTING OUTPUT TERMINALS.
WARNING
ELECTRIC SHOCK can kill.
1.- Work Weld Output Terminal.
2.- Electrode Weld Output Terminal.
3.- Access Door.
Connect cables as shown.
Close and secure access door.
2
1
3
Use only a proper torch cable
adapter positioned so it does not
hit frame, hardware, or door during
operation.
1
2
3/4" (19
m m )
Tools
Needed
Figure 3-6 Remote 14 Connections.
R C1 4
3
4
2
1
Tools needed:
1/4" (6.3 mm)
3-5 RC14 INFORMATIÓN & CONNECTIONS.
1.- Receptacle Remote RC14 (See Section 3-6)
2.- Keyway.
3.- Plug.
4.- Threated collar.
To connect this receptacle, align keyway, insert
plug, and tighten threated collar.
Electrode
Terminal
Work
Terminal
Electrode
Terminal
Work
Terminal
Summary of Contents for ALPHA TIG 252 - DP
Page 6: ......