HOST_ID=1000-0000-C921-09F7
ADAPTER_ID=1000-0000-C921-09F7
!NEWCON58
TRU64_UNIX
OTHER
1
offline
0
HOST_ID=1000-0000-C921-09F7
ADAPTER_ID=1000-0000-C921-09F7
!NEWCON59
TRU64_UNIX
THIS
1
offline
0
HOST_ID=1000-0000-C921-09F7
ADAPTER_ID=1000-0000-C921-09F7
!NEWCON60
TRU64_UNIX
OTHER
2
offline
100
HOST_ID=1000-0000-C921-09F7
ADAPTER_ID=1000-0000-C921-09F7
!NEWCON61
TRU64_UNIX
THIS
2
210513
OL this
100
HOST_ID=1000-0000-C921-086C
ADAPTER_ID=1000-0000-C921-086C
!NEWCON62
TRU64_UNIX
OTHER
1
210513
OL other
0
HOST_ID=1000-0000-C921-086C
ADAPTER_ID=1000-0000-C921-086C
!NEWCON63
TRU64_UNIX
OTHER
1
offline
0
HOST_ID=1000-0000-C921-0943
ADAPTER_ID=1000-0000-C921-0943
!NEWCON64
TRU64_UNIX
OTHER
1
210413
OL other
0
HOST_ID=1000-0000-C920-EDA0
ADAPTER_ID=1000-0000-C920-EDA0
!NEWCON65
TRU64_UNIX
OTHER
2
210513
OL other
100
HOST_ID=1000-0000-C921-086C
ADAPTER_ID=1000-0000-C921-086C
.
.
.
The following connections are shown to have nonzero offsets:
!NEWCON49
,
!NEWCON51
,
!NEWCON55
,
!NEWCON56
,
!NEWCON57
,
!NEWCON60
,
!NEWCON61
, and
!NEWCON65
4.
Set the unit offset to 0 for each connection that has a nonzero unit offset:
HSG80>
SET !NEWCON49 UNIT_OFFSET = 0
HSG80>
SET !NEWCON51 UNIT_OFFSET = 0
HSG80>
SET !NEWCON55 UNIT_OFFSET = 0
HSG80>
SET !NEWCON56 UNIT_OFFSET = 0
HSG80>
SET !NEWCON57 UNIT_OFFSET = 0
HSG80>
SET !NEWCON60 UNIT_OFFSET = 0
HSG80>
SET !NEWCON61 UNIT_OFFSET = 0
HSG80>
SET !NEWCON65 UNIT_OFFSET = 0
5.
At the console of each system accessing storage units on this HSG80,
follow these steps:
a.
Use the
wwid
manager to show the Fibre Channel environment
variables and determine which units are reachable by the system.
This is the information the console uses, when not in
wwidmgr
mode, to find Fibre Channel devices:
P00>>>
wwidmgr -show ev
wwid0
133 1 WWID:01000010:6000-1fe1-0000-0d60-0009-8080-0434-002e
wwid1
131 1 WWID:01000010:6000-1fe1-0000-0d60-0009-8080-0434-002f
wwid2
132 1 WWID:01000010:6000-1fe1-0000-0d60-0009-8080-0434-0030
wwid3
N1
50001fe100000d64
N2
N3
N4