Removal and Installation Procedures
8–3
Removal and Installation Procedures
Table 8–1 identifies the replacement methods and replacement procedures for each
enclosure element. In all cases, a power-off replacement method is possible.
CAUTION:
If a conflict exists between the replacement procedures within this
document and those within array controller-specific documentation, use procedures
in the array controller documentation.
Table 8–1 Element Replacement Methods and Procedures
Element
Recommended Replacement Method
Replacement Procedures
EMU
Hot-pluggable
I/O Module
Pluggable
1
Power Supply
Hot-pluggable (redundant power supply configuration)
ECB Battery Pack
Power-off only
ECB
Array controller dependent:
Pluggable
1
or hot-pluggable
Fan
Hot-pluggable
Array Controller
Pluggable
2
or power-off
3
Cache Module
Pluggable
2
or power-off
3
1. Requires using the field replacement utility (FRUTIL). Refer to array controller documentation for
replacement procedures.
2. Applies only to dual-redundant controller configurations. Requires using FRUTIL. Refer to array
controller documentation for replacement procedures.
3. Applies to all single-controller configurations, and dual-redundant controller configurations without
FRUTIL support.