Table 3-9
Serial Test Error Codes
Error
Code
Description
Recommended Action
1101-xx
1109-xx
Serial port test failed
Clock register test failed
The following steps apply to error
codes 1101-xx and 1109-xx:
1. Check the switch settings on the
Serial/Parallel Interface board (if
applicable) and re-test.
2. Replace the Serial/Parallel
Interface board (if applicable)
and re-test.
3. Replace the system board
and re-test.
Table 3-10
Modem Communications Test Error Codes
Error
Code
Description
Recommended Action
1201-xx
1202-xx
1203-xx
1204-xx
1206-xx
1210-xx
Modem internal loopback test failed
Modem time-out test failed
Modem external termination test failed
Modem auto originate test failed
Dial multi-frequency tone test failed
Modem direct connect test failed
The following steps apply to error
codes 1201-xx through 1210-xx:
1. Refer to the modem
documentation for correct setup
procedures and re-test.
2. Check the modem line
and re-test.
3. Replace the modem and re-test.