![Compaq 231027-002 - ProLiant - DL320R01 Reference Manual Download Page 96](http://html.mh-extra.com/html/compaq/231027-002-proliant-dl320r01/231027-002-proliant-dl320r01_reference-manual_2645014096.webp)
HP Array Configuration Utility 96
Error code Error message
Comment or clarification
2850
Controller does not support Chassis Name The controller does not support setting a chassis
name.
2851
Invalid Chassis Name
The entered chassis name is invalid. Use characters
from the set a–z, A–Z, 0–9, !, @, #, *, (, ), ,, -, _, +,
:, ., /, and [space]. The name cannot end with a
space character or exceed the maximum number of
characters allowed by the controller.
2852
Invalid SSP State
The requested SSP state is not a valid SSP state.
2853
Cannot change SSP settings
The SSP settings cannot be changed for the controller
or logical drive.
2854
Invalid SSP Adapter ID
The adapter ID is not a valid adapter ID that was
detected by the controller.
2857
Invalid Surface Scan Delay
—
2861
Controller does not support redundancy
settings
The controller is not redundant or does not support
redundancy settings.
2864
Invalid Preferred Path Mode
The specified value for the preferred path mode is
not valid, or the controller is not available.
2865
Invalid Preferred Path
The specified preferred path is not a valid chassis
slot for an available, active controller, or the
controller is not available.
2866
Failure opening capture file
<text>
—
2867
Failure opening input file
<text>
—
2868
Failure opening error file
<text>
—
2877
There are no suitable spares available
ACU found no drives that could be used as spares
for the specified array.
2880
Invalid Physical Disk Type Specified
—
2882
Invalid MNP delay
The specified value for MNP delay is invalid.
3000
Invalid Option
The value of the option supplied to this parameter is
invalid.
3002
Command Failed
The controller returned an error for a command.
3003
License Key Delete Failed
ACU is unable to delete the license key.
3004
Invalid Sector Size
—
3005
Cannot delete Array
—
3006
Invalid Number of Parity Groups
—
3007
Chassis name is too long
—
3008
Chassis name is already in use
Another controller is already using the entered
chassis name.
3009
Auto Configure failed
The Auto Configure mode was unable to complete
auto configuration.
3010
Cannot extend logical drive, not enough
free space for the requested size
—
3011
Cannot extend logical drive, requested size
is too small
—
3012
Cannot specify both SIZE and SHRINKSIZE The input file cannot specify both a SIZE and