![Compaq 133756-004 - Deskpro EN - 6550 Model 6400 Maintenance And Service Manual Download Page 84](http://html.mh-extra.com/html/compaq/133756-004-deskpro-en-6550-model-6400/133756-004-deskpro-en-6550-model-6400_maintenance-and-service-manual_2645417084.webp)
5-2
Connectors and Jumpers
5.1.2
Clearing CMOS
The computer's configuration (CMOS) may occasionally be corrupted. If it does, it is
necessary to clear the CMOS memory using jumper SW50.
To clear and reset the configuration, perform the following procedure:
1.
Prepare the computer for disassembly (Section 4.2).
CAUTION:
The power cord must be disconnected from the power source before pushing the Clear
CMOS Button (NOTE: All LEDs on the board should be OFF). Failure to do so may damage the
system board.
2.
Remove the access panel (Section 4.6).
3.
Press the CMOS button located on the system board and keep it depressed for
5 seconds.
4.
Replace the access panel.
5.
Turn the computer on.
6.
Run F10 Computer Setup (delete-utility) to reconfigure the system.
Summary of Contents for 133756-004 - Deskpro EN - 6550 Model 6400