Situation

Probable Cause

Solution

Power outlets are not working

Check power station is turned on 

and relevant outlet power is turned 

on

Turn on the power outputs by 

pressing the “Power” button for 

3 seconds after the power station 

is on. For Anderson output you will 

also need to press and hold the 

“Anderson On/Off” button for 3 

seconds

Fridge connected but 
not running

Check power station is turned on

Turn power station on

Check power station has sufficient 

charge

If low charge, charge the power 

station as per the user manual 

instructions

Check the battery monitor on the 

fridge is set to Low or Medium 

battery monitor setting

Set fridge battery monitor to the Low 

or Medium setting

Solar not charging the 
power station

Check solar is connected correctly

Check all connections from the 

solar panel to the power station are 

secure

Check solar panel is set up correctly Point solar panels towards the 

sun. Make sure there is no inline 

controller/regulator before the power 

station

DC charger not working

Check the inline fuse

If fuse is broken replace with a 10A 

blade fuse

Warning symbol is displayed

This will be caused by either over 

temperature, under temperature 

protection, overvoltage protection, 

undervoltage protection, overcurrent 

protection, short circuit protection or 

incorrect polarity protection

Remove all Inputs and Outputs and 

turn the power station off and back 

on. If the warning is still there - 

check the current temperature. The 

operating temperature should be 

between -10 and 40°. Depending 

on the temperature try moving to a 

cooler or warmer spot

TROUBLE SHOOTING

Summary of Contents for 10000071

Page 1: ...ROVER LiTHIUM 40AH POWER STATION OWNERS MANUAL Part No 10000071...

Page 2: ...fied persons in order to avoid a hazard This product must not be used by persons including children with reduced physical or mental capabilities Also this product is not to be used by a person who has...

Page 3: ...40 degrees Make sure the device you are connecting is switched off before you connect it Switch the unit off immediately if it has accidentally fallen been dropped or was exposed to vibrations DO NOT...

Page 4: ...OFF 3 2 X USB OUTPUT 1 X USB C OUTPUT 4 2 X DC5525 OUTPUT 5 12V CIGARETTE SOCKET OUTPUT 6 LCD DISPLAY 7 LED LIGHT POWER BUTTON 8 LED LIGHT 9 DC AC OR SOLAR INPUT 10 ANDERSON OUTPUT 50A CONNECTOR 11 1...

Page 5: ...scharge What the LCD screen displays depends on the Input and Output For example if two phones are attached the screen will show the below If an AC adaptor is also connected to the input the screen wi...

Page 6: ...tep 1 Turn on the power station by holding the power button for three seconds Step 2 Insert the adaptor plug into the input socket on the side of the power station and plug it in to mains 240V AC Turn...

Page 7: ...wer source Step 3 The power station will automatically begin to charge The battery status will be shown on the LCD display and will also show the minutes remaining until fully charged Note The LCD dis...

Page 8: ...onds Step 2 Insert the adaptor plug into the input socket on the side of the power station and other lead to your solar panel Anderson connector Step 3 The power station will automatically begin to ch...

Page 9: ...ton for 3 seconds USB Outputs There are two USB outlets with 2 Amp output per port and one USB Type C with 3 Amp maximum output To use this output you need to turn on the power station and then press...

Page 10: ...ent protection short circuit protection and incorrect polarity protection If these are activated the following symbol will be displayed on the screen Remove all Inputs and Outputs and turn the power s...

Page 11: ...the battery or storing it for too long without charging it may cause permanent damage to the battery For further information or assistance please contact Customer Service on 1300 555 197 or email serv...

Page 12: ...ar not charging the power station Check solar is connected correctly Check all connections from the solar panel to the power station are secure Check solar panel is set up correctly Point solar panels...

Page 13: ...V 1 5A USB Type C Output Anderson Output 5V 9V 12V 15V 20V 3A 50A Connector 12 14V 10A DC Outputs Maximum DC Output 10A Combined 140W 1 x 2 Pin 12 14V 10A 1 x Cigarette Socket 12 14V 10A 2 x DC5525 12...

Page 14: ...14 NOTES...

Page 15: ...we may at its discretion substitute a model of equivalent nature where the exact model is unavailable c this Limited Warranty does not apply to damage caused by failure and damage caused by improper...

Page 16: ...ered trademark of Primus Australia Pty Ltd Designed Imported by Adventure Trading Australia Pty Ltd 71 Charles Ulm Place Eagle Farm QLD 4009 AUSTRALIA Made in China WARRANTY For details see www compan...

Reviews: