Routine Service and Maintenance
d. Replace hydraulic filter. See
page 4-9
, Step 3.
The hydraulic dipstick is located underneath the hydraulic filler cap,
located on top of the upper hydraulic tank. See
Figure 4–16
.
e. Unscrew the dipstick assembly and remove from the machine. (1,
Figure 4–16
) and fill the
hydraulic tank with the proper hydraulic fluid (Chevron Rykon Premium ISO 46 or
equivalent) until the fluid level is at but not above the upper marker hole in the dipstick.
Do not over fill the hydraulic system. Damage to the hydraulic system might result.
f. Start the machine and run the engine at low idle for several minutes. Shut off the engine.
g. Recheck the hydraulic fluid level as described above.
Figure 4–16 Hydraulic Oil Check and Fill