background image

 

 

Con
dition
s of Use

 

Conditions of Use 

 

Read this manual completely before working on, 

or making adjustments to, the Compac 

equipment 

 

Compac Industries Limited accepts no liability for 

personal injury or property damage resulting 

from working on or adjusting the equipment 

incorrectly or without authorization.  

 

Along with any warnings, instructions, and 

procedures in this manual, you should also 

observe any other common sense procedures 

that are generally applicable to equipment of this 

type. 

 

Failure to comply with any warnings, 
instructions, procedures, or any other common 

sense procedures may result in injury, equipment 

damage, property damage, or poor performance 

of the Compac equipment 

 

The major hazard involved with operating the 

Compac C4000 processor is electrical shock. 

This hazard can be avoided if you adhere to the 

procedures in this manual and exercise all due 

care. 

 

Compac Industries Limited accepts no liability for 

direct, indirect, incidental, special, or 

consequential damages resulting from failure to 

follow any warnings, instructions, and 

procedures in this manual, or any other common 

sense procedures generally applicable to 

equipment of this type. The foregoing limitation 

extends to damages to person or property 

caused by the Compac C4000 processor, or 

damages resulting from the inability to use the 

Compac C4000 processor, including loss of 

profits, loss of products, loss of power supply, 

the cost of arranging an alternative power 

supply, and loss of time, whether incurred by the 

user or their employees, the installer, the 

commissioner, a service technician, or any third 

party.  

 

Compac Industries Limited reserves the right to 

change the specifications of its products or the 

information in this manual without necessarily 

notifying its users. 

 

 

Variations in installation and operating conditions 

may affect the Compac C4000 processor's 

performance. Compac Industries Limited has no 

control over each installation's unique operating 

environment. Hence, Compac Industries Limited 

makes no representations or warranties concerning 

the performance of the Compac C4000 processor 

under the actual operating conditions prevailing at 

the installation. A technical expert of your choosing 

should validate all operating parameters for each 

application. 

 

Compac Industries Limited has made every effort to 

explain all servicing procedures, warnings, and 
safety precautions as clearly and completely as 

possible. However, due to the range of operating 

environments, it is not possible to anticipate every 

issue that may arise. This manual is intended to 

provide general guidance. For specific guidance and 

technical support, contact your authorised Compac 

supplier, using the contact details in the Product 

Identification section. 

 

Only parts supplied by or approved by Compac may 

be used and no unauthorised modifications to the 

hardware of software may be made. The use of non-

approved parts or modifications will void all 

warranties and approvals. The use of non-approved 

parts or modifications may also constitute a safety 

hazard. 

 

Information in this manual shall not be deemed a 

warranty, representation, or guarantee. For warranty 

provisions applicable to the Compac C4000 

processor, please refer to the warranty provided by 

the supplier. 

 

Unless otherwise noted, references to brand names, 

product names, or trademarks constitute the 

intellectual property of the owner thereof. Subject to 

your right to use the Compac C4000 processor, 

Compac does not convey any right, title, or interest 

in its intellectual property, including and without 

limitation, its patents, copyrights, and know-how.  

 

Every effort has been made to ensure the accuracy 

of this document. However, it may contain technical 

inaccuracies or typographical errors. Compac 
Industries Limited assumes no responsibility for and 

disclaims all liability of such inaccuracies, errors, or 

omissions in this publication. 

 

Summary of Contents for OPT SCR200

Page 1: ...OPT SCR200 Installation Manual Version No 1 0 3 Model OPT Mark 2 SCR200 Date 7th December 2018...

Page 2: ...ac C4000 processor s performance Compac Industries Limited has no control over each installation s unique operating environment Hence Compac Industries Limited makes no representations or warranties c...

Page 3: ...t any time This publication describes the state of the product at the time of publication and may not reflect the product at all times in the past or in the future Manufactured By The Compac OPT SCR20...

Page 4: ...ion Date 06 03 2018 Authorised By W Zheng File Name OPT SCR200 Installation Manual Revision History Version Date Author s Revision Notes 1 0 0 06 Mar 2018 S Laycock New Manual 1 0 1 20 Mar 2018 S Layc...

Page 5: ...ts 2 Tools Checklist 3 Precautions 4 Mechanical Installation 5 Mounting the OPT on a Post 6 Electrical Installation 7 Cable Requirements 7 Electrical Testing 9 Tank Gauging Setup 11 System and Transac...

Page 6: ...1 Footprints Footprints Base Footprint External Dimensions...

Page 7: ...Secure Card Reader Camlock Optional IP Phone Speaker Payment Express SKP200 PIN pad Privacy Shield Optional IP Phone Mic and Button Vent Security PIN pad Optional 3G Router Net Switch MX Box UPS Board...

Page 8: ...iver 7mm nut driver 8mm nut driver T30 Torx drive bit or driver T10 Torx drive bit or driver Metric spanner set Metric 3 8 or 1 4 drive socket set 1 4 screwdriver bit holder 1 4 A F spanner 6 adjustab...

Page 9: ...nser The OPT should be placed at least 0 5 metres from any flammable liquid fuel dispensers and 1 5 metres from any LPG dispensers The OPT should be mounted so that the base of the cabinet is at least...

Page 10: ...lowing equipment Mechanical and electrical tools Multimeter Fastenings to mount the OPT Security key drivers Security TORX or unique security key if Extra Security equipped A fully charged laptop comp...

Page 11: ...OPTs do not have the bolt covers Fasten using the supplied galvanised bolts with the rounded head facing out and a flat washer under the nut To mount the OPT onto the post OPTs with the extra securit...

Page 12: ...ed depending on the brand of pump on site Correct polarity must be observed NOTE For pump comms tank gauging and ADSL connections it is suggested that the wires are crimped to a ferrule to provide a g...

Page 13: ...le at the bottom of the aerial for when the spring flexes A loop of 50mm before fixing the cable should be sufficient The aerial plugs into the wireless router Neatly cable tie the aerial cable to exi...

Page 14: ...turned on two LEDs above the power switch should turn on LED labelled D5 indicates the 230V mains power is OK D6 indicates the battery is connected and OK If D6 does not light up when then unit is fi...

Page 15: ...10 Electrical Testing UPS Board LEDs FMS Board LEDs Diagnostic LEDs...

Page 16: ...hecks to confirm this The exact site test setup and procedure will vary from customer to customer but as a minimum we would suggest the following Check that the current price is correct Check each dis...

Page 17: ...ounted appropriately Wireless internet OPTs Check that the pump comms have been connected Check that the tank gauging is connected and operating correctly where fitted Replace ATG cable to OPT where p...

Page 18: ...orrect Tank Information Tests where fitted Yes No Check that tanks are set up in CompacOnline and that correct information from the equipment is being displayed on screen Check that the correct fuels...

Reviews: