9. 

Dispensing Hoses and Nozzles 

The unit may or may not be supplied with dispensing hose and nozzle assemblies.  
If customer supplied hose assemblies, pylons, reels, safe breaks and nozzles are used they must 
comply with the requirements outlined in AS/NZS 222. 
 

9.1 

Breakaways 

 
For all dispensers fitted with breakaways, ensure the breakaway is installed between the nozzle 
and the high-mast or pylon (if fitted). Any breakaways that have been subject to a break-away 
situation should be inspected and refitted or replaced in accordance with the original 
manufacturer’s instructions. 

10. 

Setting up the C4000  

 

Once the pump is connected on site, the final setup check and calibration to complete the 
installation must be carried out, using the Parameter Switch and Calibration (K-Factor) Switch. 
These switches are found on the C4000 Microprocessor Board which is housed in a metal 
enclosure located behind one of the inner column panels. 

 

10.1 

Configuration Code 

 

The configuration code has been set at Compac and should not be changed   
In the event of it being lost and having to be re-entered the configuration is written on the yellow 
label on the C4000 processor board cover. 
 

10.2 

Submersible Delay (Sd) 

  

This is the time delay from when the Submersible pump starts to when the  solenoids in the 
dispenser open to allow time for the leak detector to reset. 
This is factory set by Compac at 005 (five seconds).  
If problems are experienced with the leak detector tripping, firstly check that 'Sd' is still set and 
then, if necessary, make it longer as follows. 

 

1. Press and release the K factor switch repeatedly until 'Sd' appears on the Dollar display 
'dXXX' will appear in the litres display.  
 
2. Continue to press the K factor switch until the number to be changed flashes. Hold the switch 
down and this number will then increment. 
 
3. Release the switch when the required number is displayed. The value of the displayed number 
will then be stored in the C4000 memory as the Submersible Delay. 
 

10.3 

Parameter Switch Settings 

10.3.1 

Setting the Pump Number  

This must be set at the pump, for each hose, so that communications with  
a controller can take place. The location of this switch is shown in the  
diagram below. 
Depress the Parameter Switch nine (9) or more times until the message  

'PnA XX' 

appears in the litres display window.  When the switch is  

pressed again 

'Pnb XX 

' will appear on the display. These two options 

 will toggle each time the switch is pressed. To alter either of the pump numbers, press and hold 
the Parameter Switch when the pump number to be altered appears on the display. This number 
will then increment. The switch should be released when the desired pump number is displayed. 
The value of the displayed number will then be stored in the C4000 memory as the pump 
number for that hose. 

NOTE

: For a single hose only 

‘Pn”

 will appear 

Summary of Contents for L160SD

Page 1: ...se Auckland 1061 New Zealand PO Box 12 417 Penrose Auckland 1642 New Zealand Tel 64 9 579 2094 Fax 64 9 579 0635 info compac co nz www compac co nz Installation and Setup Instructions Model Laser Vers...

Page 2: ...ctrical Connections 7 8 1 Submersible Pump connections 7 9 Dispensing Hoses and Nozzles 8 9 1 Breakaways 8 10 Setting up the C4000 8 10 1 Configuration Code 8 10 2 Submersible Delay Sd 8 10 3 Paramete...

Page 3: ...tallation and operating conditions may affect the unit s performance Compac Industries Limited has no control over each installation s unique operating environment Hence Compac Industries Limited make...

Page 4: ...Cilaklfs1 shrdata Masters Installation Sheets Laser L160SD Installation Sheet doc Page 4 of 16 2 Footprint Outlets are approximately 680mm above the base Pump outlet size 160 l min 1 BSP female socket...

Page 5: ...in transit in particular damage to electronics due to vibration or jarring All terminals and plugs should be checked including IC chips to ensure they are securely in place 5 Installation Installation...

Page 6: ...tches while working in the Flame proof box Operating the unit with these incorrectly set can result in damage to the C4000 Power Supply or incorrect operation of the triacs These switches are set in t...

Page 7: ...flameproof enclosure ensure the sealing O ring is in place Note All cables entering the power supply must be glanded with approved 20mm flameproof glands Note Output to submersible pump s is 230 V ac...

Page 8: ...en the solenoids in the dispenser open to allow time for the leak detector to reset This is factory set by Compac at 005 five seconds If problems are experienced with the leak detector tripping firstl...

Page 9: ...he litres display and PrA is displayed on the money display 3 Press and hold the Parameter switch A digit of the displayed Price per litre will begin to increment 4 When the digit is correct release t...

Page 10: ...Factor switch is shown in the diagram below J1 Comms Test J7 Displays J13 Not used J2 To Power Supply J8 Temperature for Temperature compensation only J14 Not used J3 Input from KG Meter Side A J 9 P...

Page 11: ...a certified measuring container and compare the display value with the amount dispensed Example Display shows 10 00 True volume 20 00 To calculate the correct K Factor from the information above firs...

Page 12: ...code to run Standalone without Dispenser Controller is 0000 The b code to inhibit Standalone is 1000 13 Spare Fuses In the event of a fuse blowing on the C4000 Power supply a bag of 3 is included in e...

Page 13: ...xceeded Err 8 Excess reverse rotation of encoder Check product is not flowing back into the tank once the delivery has finished Err 9 Faulty or disconnected meter encoder 1 Check that encoder is plugg...

Page 14: ...terface Board F CP CI192 MKIPT Tote F BA TOTE A K C4000 Microprocessor Board F CP C4PROCES A Nozzle Holder F NOZL HLDR M5SR COM125 Meter complete F METER COM125 K COM125 Meter electronics only F METER...

Page 15: ...the unit Phone number if dial in site Merchant ID number Eftpos site 18 Contact Details Service Agent Phone E mail Address 1 Address 2 19 Notes Manufacturer Contact Details The Compac Laser Dispenser...

Page 16: ...of changes 20 05 2010 Added Conditions of Use 12 06 2012 Added generator power and breakaway info Updated C4000 wiring 19 06 2013 Updated wiring info spare parts 17 October 2013 Added sump info in ac...