3. 

Static Electricity Precautions 

Electronic components used are sensitive to static. Please take anti-static precautions. 
An anti-static wrist strap should be worn and connected correctly when working on any 
electronic equipment. If an anti-static wrist strap is unavailable, or in an emergency, hold onto 
an earthed part of the pump/dispenser frame whilst working on the equipment. This is not a 
recommended alternative to wearing an anti-static wrist strap. 
Note: 

Compac Industries Limited reserves the right to refuse to accept any circuit boards 

returned, if proper anti-static precautions have not been taken. 

 

4. 

Pre-installation  Check 

Once the pump is received on site, check that no damage has occurred while in transit – in 
particular, damage to electronics due to vibration or jarring. All terminals and plugs should be 
checked, including IC chips, to ensure they are securely in place. 

 

5. 

Installation 

Installation should be in accordance with local regulations. 
The dispensing equipment shall be installed to prevent the delivery hose from contacting the 
ground when not in use. 
 
Where local regulations require a sump to be fitted: 

a.

 

Sumps must be provided at all dispenser installations with secondary containment pipework 

and at all new installations. 

b.

 

At all sites with sumps, dispensers should be installed with a liquid level detection device 

fitted in the sump that will raise an alarm if liquid is detected in the base of the sump. 

6. 

Comms Dip-switch settings 

6.1 

Standard Pump Comms Setting  

(Dipswitch SW3) 
1-ON 
2-OFF 
3-ON 
4-OFF 
These are factory set to the standard setting unless ordered otherwise.eg Gilbarco. 

 

6.2 

Gilbarco Pump comms Setting  

(Special software and interface board required) 
1-OFF 
2-ON 
3-OFF 
4-ON 

Summary of Contents for L160SD

Page 1: ...se Auckland 1061 New Zealand PO Box 12 417 Penrose Auckland 1642 New Zealand Tel 64 9 579 2094 Fax 64 9 579 0635 info compac co nz www compac co nz Installation and Setup Instructions Model Laser Vers...

Page 2: ...ctrical Connections 7 8 1 Submersible Pump connections 7 9 Dispensing Hoses and Nozzles 8 9 1 Breakaways 8 10 Setting up the C4000 8 10 1 Configuration Code 8 10 2 Submersible Delay Sd 8 10 3 Paramete...

Page 3: ...tallation and operating conditions may affect the unit s performance Compac Industries Limited has no control over each installation s unique operating environment Hence Compac Industries Limited make...

Page 4: ...Cilaklfs1 shrdata Masters Installation Sheets Laser L160SD Installation Sheet doc Page 4 of 16 2 Footprint Outlets are approximately 680mm above the base Pump outlet size 160 l min 1 BSP female socket...

Page 5: ...in transit in particular damage to electronics due to vibration or jarring All terminals and plugs should be checked including IC chips to ensure they are securely in place 5 Installation Installation...

Page 6: ...tches while working in the Flame proof box Operating the unit with these incorrectly set can result in damage to the C4000 Power Supply or incorrect operation of the triacs These switches are set in t...

Page 7: ...flameproof enclosure ensure the sealing O ring is in place Note All cables entering the power supply must be glanded with approved 20mm flameproof glands Note Output to submersible pump s is 230 V ac...

Page 8: ...en the solenoids in the dispenser open to allow time for the leak detector to reset This is factory set by Compac at 005 five seconds If problems are experienced with the leak detector tripping firstl...

Page 9: ...he litres display and PrA is displayed on the money display 3 Press and hold the Parameter switch A digit of the displayed Price per litre will begin to increment 4 When the digit is correct release t...

Page 10: ...Factor switch is shown in the diagram below J1 Comms Test J7 Displays J13 Not used J2 To Power Supply J8 Temperature for Temperature compensation only J14 Not used J3 Input from KG Meter Side A J 9 P...

Page 11: ...a certified measuring container and compare the display value with the amount dispensed Example Display shows 10 00 True volume 20 00 To calculate the correct K Factor from the information above firs...

Page 12: ...code to run Standalone without Dispenser Controller is 0000 The b code to inhibit Standalone is 1000 13 Spare Fuses In the event of a fuse blowing on the C4000 Power supply a bag of 3 is included in e...

Page 13: ...xceeded Err 8 Excess reverse rotation of encoder Check product is not flowing back into the tank once the delivery has finished Err 9 Faulty or disconnected meter encoder 1 Check that encoder is plugg...

Page 14: ...terface Board F CP CI192 MKIPT Tote F BA TOTE A K C4000 Microprocessor Board F CP C4PROCES A Nozzle Holder F NOZL HLDR M5SR COM125 Meter complete F METER COM125 K COM125 Meter electronics only F METER...

Page 15: ...the unit Phone number if dial in site Merchant ID number Eftpos site 18 Contact Details Service Agent Phone E mail Address 1 Address 2 19 Notes Manufacturer Contact Details The Compac Laser Dispenser...

Page 16: ...of changes 20 05 2010 Added Conditions of Use 12 06 2012 Added generator power and breakaway info Updated C4000 wiring 19 06 2013 Updated wiring info spare parts 17 October 2013 Added sump info in ac...

Reviews: