10.3. Grinding group maintenance
For grinding group maintenance, follow these instructions:
Turn off the machine using the On-Off switch (14 Elite – 10 Touch
position 0). Disconnect the machine from the power supply. Loos-
en the setting roller (5), as shown in Fig. 1, and remove the hopper
(2) from the grind regulator (6).
Release the position indicator cover (7) with a flat-head screw-
driver as shown in Fig. 11 and loosen the screw below it with a
Phillips screwdriver.
Turn the grind regulator (6) clockwise as in Fig. 12, until it lifts off.
Using a small brush or vacuum, clean the inside of the grinding
chamber. Check the condition of the burrs and change them, if
necessary. If not, put the regulator back in place, turning it counter-
clockwise until the burrs touch and replace the position indicator
screw and cover (7) as shown in Fig. 11 &12.
10.4. Accessing the burrs
Follow the instructions in 10.3. in order to remove the grind regu-
lator (6), removing the position indicator screw and cover (7) as
explained in Fig. 11. Once you have removed the grind regulator,
you will see that it is attached to the upper burr holder allowing
you to manipulate the upper and lower burrs as shown in Fig. 13.
After changing the burrs, assemble the upper burr holder by
threading it counter-clockwise, replace the grind regulator (6) and
follow the instructions as shown in Fig 11 & 12.
Fig. 13
Fig. 11
Unthreading
direction
Threading
direction
Fig. 12