INS_FVT/FVR412_REV–

05/27/10

PAGE 5

TECH SUPPORT: 1.888.678.9427

INSTALLATION AND OPERATION MANUAL 

FVT/FVR412

FIGURE 7 – LED INDICATORS

FIGURE 6 – CONTACT SWITCH POSITIONS

LINK

VIDEO (1 – 8)

DATA (1 – 2)

POWER

GREEN

Communication link has been 

established over optical fiber

Active video signal present 

on the BNC connector.

Active data signal 

present

Unit powered up

RED

Communication link has not been 

established

No video signal

No data signal

OFF

Not powered up correctly

Unit powered down

The four CONTACT switches on the front of the unit set the operating mode of the 
CONTACT OUT terminal pair.

It can either function as an alarm to indicate fault conditions, or it can function as a 
contact closure to indicate the state of the CONTACT IN terminal pair on the rear of 
the unit at the other end of the fiber.

1

2

3

4

ON

OFF

OFF

OFF

Closed when optical Port has established link. 

Open when Optical Port has lost link.

ON

ON

ON

OFF

Closed when Optical Port has established link and all video signals are present. 

Open when Optical Port has lost Link, or if a Video signal is lost.

ON

ON

ON

ON

Contact Closure mode. 

State based on CONTACT IN at other end of fiber link.

Summary of Contents for ValueLine FVT412

Page 1: ...rdened and suitable for use in unconditioned roadside or out of plant installations The FVT FVR412 is compatible with NTSC PAL and SECAM video transmission protocols and supports bi directional RS232 422 and 485 2 4 Wire data See Figure 4 on Page 3 for data selection See Figure 6 on Page 5 for contact switch positions Bi Color LED indicators are provided to indicate the status of the system video ...

Page 2: ...NSMITTER AND RECEIVER FIGURE 3 FVR412 RECEIVER INSTALLATION AND OPERATION MANUAL FVT FVR412 TECH SUPPORT 1 888 678 9427 NOTE Remove Electrical Connector for Rack Mount Units MULTIMODE OR SINGLE MODE OPTICAL FIBER BLACK BLACK WITH WHITE STRIPE REAR PANEL REAR PANEL FRONT PANEL FRONT PANEL ...

Page 3: ...he front panel of the unit Switch 4 RS485 4 Wire 1 2 1 2 1 2 1 2 1 RS232 2 RS422 Bi Phase or Manchester 3 RS485 2 Wire Sensornet 1 RS232 DIN DOUT GND 2 RS422 Bi Phase Manchester DIN DIN DOUT DOUT GND 3 RS485 2 Wire Sensornet DIN DIN GND 4 RS485 4 Wire DIN DIN DOUT DOUT GND Termination Note A 120 ohm termination resistor is applied to the differential inputs when TERM is wired directly to DIN see d...

Page 4: ...ta Out Data Out 2 Wire RS 485 Sensornet DIN DIN DIN DIN Data A Data B Data A Data B Data Transmit Data Receive Signal Ground DIN DOUT GND DOUT DIN GND Data Receive Data Transmit Signal Ground 4 Wire RS 485 DIN DIN DOUT DOUT DOUT DOUT DIN DIN Data Out A Data Out B Data In A Data In B Data In A Data In B Data Out A Data Out B DIN DIN DOUT DOUT DOUT DOUT DIN DIN Data Out Data Out Data In Data In Data...

Page 5: ... down The four CONTACT switches on the front of the unit set the operating mode of the CONTACT OUT terminal pair It can either function as an alarm to indicate fault conditions or it can function as a contact closure to indicate the state of the CONTACT IN terminal pair on the rear of the unit at the other end of the fiber 1 2 3 4 ON OFF OFF OFF Closed when optical Port has established link Open w...

Page 6: ...oriented right side up and slide it into the card guides in the rack until the edge connector at the back of the card seats in the corresponding slot in the rack s connector panel Seating may require thumb pressure on the top and bottom of the card s front panel CAUTION Take care not to press on any of the LEDs 2 Tighten the two thumb screws on the card until the front panel of the card is seated ...

Reviews: