INS_FDW1000_EXP101 01/06/2020 PAGE 4
INSTALLATION AND OPERATION MANUAL
FDW1000 / EXP101
TECH SUPPORT: 1.888.678.9427 / +44 (0)203 630 1653
Specifications
The following specifications apply to all of the items in this series
Power
•
operating voltage range = DC 8 to 12 V,
•
power consumption < 6 W each
•
hardened power supply item number PS-AMR5-12 as needed
Inputs and outputs
Data
•
Wiegand (max 248 bits pass through, filter the first eight bits unless Wiegand No Filter is
active)
•
strobed (clock and data)
•
F/2F unsupervised
LED
•
DC 0 to 30 V
Contact closure (relay) channels
Relay Channels 1 and 2
•
FDW1000/C and EXP101/C central units will each accept up to two dry contact closures as
inputs – RELAY 1 IN and RELAY 2 IN – and pass the status of each contact to corresponding
FDW1000/R and EXP101/R remote units, each containing two single-pole, double-throw relays
– RELAY 2 OUT and RELAY 2 OUT.
Relay Channels 3 and 4
•
FDW1000/R and EXP101/R remote unit will each accept up to two dry contact closures as
inputs – RELAY 3 IN and RELAY 4 IN – and pass the status of each contact to corresponding
FDW1000/C and EXP101/C central units, each containiing two single-pole, double-throw relays
– RELAY 3 OUT and RELAY 4 OUT.
Relay Contact Ratings
•
DC 30 V, 1.0 A, resistive loads only, 1 × 105 operations at +room temperature (+20°C or+68°F)
•
AC 125 V, 0.3 A, resistive loads only, 1 × 105 operations at +room temperature (+20°C or+68°F)