![Comnet EXP100C Installation And Operation Manual Download Page 11](http://html.mh-extra.com/html/comnet/exp100c/exp100c_installation-and-operation-manual_2644247011.webp)
INS_FDW1000_EXP101 01/06/2020 PAGE 11
INSTALLATION AND OPERATION MANUAL
FDW1000 / EXP101
TECH SUPPORT: 1.888.678.9427 / +44 (0)203 630 1653
Programming
•
Remove power from the FDW1000/C.
•
Turn all DIP switches OFF.
•
Using DIP Switches 6, 7, and 8, set the communications format using the following table:
Communications Format
DIP Switch 6
DIP Switch 7
DIP Switch 8
not used during programming
OFF
OFF
OFF
Wiegand
OFF
OFF
ON
Wiegand, no filter
OFF
ON
OFF
strobed rising edge (MR-5)
OFF
ON
ON
strobed rising edge (Dorado 644)
ON
OFF
OFF
strobed rising edge (Mag-Tek)
ON
OFF
ON
strobed falling edge
ON
ON
OFF
unsupervised F/2F
ON
ON
ON
•
Apply power to the FDW1000/C. The device is now ready to use.
A common ground connection is critical for proper operation. At each remote location, a common
ground must exist between the reader(s), the FDW1000/R, and any EXP100/Rs. At the central loca-