QSG_CWFE2SC(M,S)2 Rev. 11.17.17 PAGE 8
INSTRUCTION MANUAL
CWFE2SC(M,S)2
TECH SUPPORT: 1.888.678.9427
Problem Solving
»
Check the DIP-switch configuration. It must be set in the same operational mode as the
corresponding link.
»
Select the proper UTP/fiber optic cable to construct your network. The single-mode media
converter must use single-mode fiber optic cable. Please check that you are using the right
cable.
Optical Fiber Specifications
The following table shows the optical Fiber Specification
Module Name
Wavelength (nm)
Avg. Launch Power (dB)
Avg. Sensitivity (dB)
CWFE2SCM2
1310 nm
-20 dB
-30 dB
CWFE2SCS2
1310 nm
-15 dB
-30 dB
Module Name
Avg. Power Loss Budget (dBm) Max. FDX Fiber Distance (Km)
Fiber Size (um)
CWFE2SCM2
10 dBm
3 km
62.5/125
50/125
CWFE2SCS2
15 dBm
30 km
9/125
Optical Specifications of Transceivers
1310 nm
Multimode
Single Mode
Transmitter (Output Center Wavelength): 1261~1360 nm
Receiver (Wavelength of Operation): 1100~1600 nm