background image

 

 

 

Page 2 

 

 

 

 

 

AT

FI

IT

PL

UK

RO

BE

FR

LV

PT

IS

TR

CY

DE

LT

SK

LI

HR

CZ

EL

LU

SI

NO

DK

HU

MT

ES

CH

EE

IE

NL

SE

BG

Brazil Statement 

For Brazil, those products are designed for specific application and needs to be installed by a qualified personal who has RF and related rule knowledge.  Regarding the 

operation on range of 5150 MHz to 5350 MHz, the average output power of the equipments must be adjusted to the maximum limit of - 0,48 dBm and for 5470 MHz to 5725 

MHz, the average output power of the equipments must be adjusted to the maximum limit of 6,44 dBm 

Para o Brasil, esses produtos são projetados para aplicações específicas e necessidades a serem instalados por um pessoal qualificado que tenha conhecimento regra RF e 

afins.Em relação à operação em série de 5150 MHz a 5350 MHz, a potência média de saída dos equipamentos deve ser ajustado para o limite máximo de - 0,48 dBm e para 

5470 MHz a 5725 MHz, a potência média de saída dos equipamentos deve ser ajustada ao limite máximo de 6,44 dBm . Este equipamento opera em caráter secundário, isto 

é, não tem direito a proteção contra interferência prejudicial, mesmo de estações do mesmo tipo, e não pode causa interferênc ia a sistemas operando em caráter primário 

Hong Kong Statement 

The 5.15 – 5.35 GHz band shall be restricted to indoor operations only.  Obey local regulations when using this product. 

Taiwan Statement

 

1. 

無 線 資訊傳輸設備避免影響附近雷達系統之操作

 

2. 

本 器 材須經專業工程人員安裝及設定,始得設置使用,且不得直接販售給一般消費者

 

經 型 式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變更頻率、加大功率或變更原設計之特性及功能。

  

低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應立即停用,並改善至無干擾時方得繼續使用。前項合法通信,指依電信法規定作業之無線電
通 信 。低功率射頻電機須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之干擾

The control, adjustment and on/off operation of this device does not violate the “Administrative regulations on low power radio waves radiated devices”. Any adjustments to 

the device should be carried out or be monitored by a specialist who has expertise on radio frequency devices. Replacement of components which may lead to the violation to 

the regulations is not allowed. Without permission granted by the NCC, any company, enterprise, or user is not allowed to change frequency, enhance transmitting power or 

alter original characteristic as well as performance to an approved low power radio-frequency devices. The low power radio-frequency device shall not influence aircraft 

security and interfere with legal communications; if found, the user shall cease operating immediately until no interference is achieved. The said legal communications means 

radio communications is operated in compliance with the Telecommunications Act. The low power radio-frequency devices must not be susceptible with the interference from 

legal communications or ISM radio wave radiated devices. 

限用物質含有情況標示聲明書

 

 

設備名稱:無線網路基地台,型號(型式)

T750, T750SE 

Equipment name                 Type designation (Type) 

單元U

nit

 

限用物質及其化學符號

  

Restricted substances and its chemical  symbols 

 

Lead (Pb) 

Mercury 

(Hg) 

Cadmium 

(Cd) 

六價鉻

Hexavalent 

chromium (Cr

+6

多溴聯苯

Polybrominated 

Biphenyls (PBB) 

多溴二苯醚

Polybrominated 

diphenyl ethers  (PBDE) 

Enclosure - Top 

頂部外殼

 

Enclosure - Bottom 

底部外殼

 

PWB 

電路板

 

 

Connector and Receptacle 

插口

 

備考

1.

〝超出

0.1  wt  %

〞及〝超出

0.01  wt  %

〞係指限用物質之百分比含量超出百分比含量基準值。

 

備考

2.

O

〞係指該項限用物質之百分比含量未超出百分比含量基準值。

 

備考

3.

〝-〞係指該項限用物質為排除項目。

 

 

 

European Union Notices and National Restrictions 
EU Declaration of Conformity 

 

This declaration of conformity is issued under the sole responsibility of the manufacturer (or installer): 

Ruckus Wireless, Inc. - 350 West Java Drive, Sunnyvale, CA 94089 USA 

+1-650-265-4200 

 

The object of the declaration is in conformity with Directive 2014/53/EU of the European Parliament and of the Council of 16 April 2014 and Directive 2011/65/EU of the 

European Parliament and of the Council of 8 June 2011 on the harmonisation of the laws of the Member States relating to the making available on the market of radio 

equipment.  The following standards were applied during the assessment of the product: 

 

Radio: ETSI EN 300 328, ETSI EN 301 893, ETSI EN 302 502, EN 303 413 

 

EMC: EN 55032, EN 301 489-1, EN 301 489-17, EN 301 489-19 

 

Safety: IEC/EN/UL 60950-1, IEC/EN/UL 62368-1, EN 62311, EN 50385, EN 50665 

 

The frequency band 5150 – 5350 MHz is restricted to indoor use.  The frequency band 5725 – 5875 MHz are non-harmonized frequencies.  Use is restricted to outdoor 

professionally installed access points as allowed by local authorities. 

 

Maximum output power: 

—2400-2483.5MHz: 19.9dBm EIRP

 

—5150-5350MHz: 22.9dBm EIRP 

—5470-5725MHz: 29.9dBm EIRP 

—5725-5875MHz: 35.9dBm EIRP  

 

Note 1

“Exceeding  0.1 wt %” and “exceeding  0.01 wt %” indicate that the percentage  content of the restricted substance

 

exceeds  the 

reference  percentage  value  of presence  condition.

 

Declaration of the Presence Condition of the Restricted Substances Marking 

Note 2

“○” indicates that the percentage  content of the restricted  substance does not exceed  the percentage  of reference  value  of presence.

 

Note 3

The “−” indicates that the restricted  substance corresponds  to the exemption. 

Summary of Contents for RUCKUS

Page 1: ...ireless com warranty Before deploying your RUCKUS WIRELESS Access Point verify that all items listed in Package Contents are included in the package If any item is damaged or missing notify your authorized RUCKUS WIRELESS sales representative Also make sure that you have the required hardware and tools Required Hardware and Tools 1 2 13 mm flat blade screwdriver or equivalent No 2 Phillips screwdr...

Page 2: ...gland base 8 Tighten the cable gland dome to 7 in lbs The SFP module is hot swappable and can be removed with fingers or simple tools Connecting the SFP Optic Module Using a Zipcord Cable You can use a zipcord cable to connect to the SFP optic module WARNING The zipcord fiber cable is extremely fragile and must be handled with care NOTE Do not insert the cable gland base grommet dome into the exte...

Page 3: ...tical pole 4 Continue with Mounting the Linkage Bracket to the U Joint Bracket on page 3 Mounting the Linkage Bracket to the U Joint Bracket 1 The linkage bracket attaches to the U joint bracket using an M8 bolt and washer set The linkage bracket is symmetrical and either end can be attached to the U joint bracket NOTE Make sure that linkage bracket is installed with its serrated external tooth lo...

Page 4: ... 6 N m 120 in lbs 3 Continue with Powering the AP with AC on page 7 External Antenna and Cabling Need to be Purchased Separately If the External Antenna option is chosen over the internal sector antenna the External Antenna and Antenna Cable must be purchased separately NOTE Beamflex is not available with external antennas Mounting and Connecting 5 GHZ and 2 5 GHZ External Antennas NOTE Mount the ...

Page 5: ...t covers the connector thread between the cable coupling nut and the base of the connector Make sure that the final wrap is approximately flush with the cable coupling nut and then cut the sealing tape FIGURE 13 Wrapping the Exposed Connector Threads NOTE Cut do not tear the sealing tape If the sealing tape is overstretched it loses its self amalgamating properties Step 4 Wrapping the Internal Lay...

Page 6: ...p Loops Physically mount the AP and antennas at your desired location preferably on the same mounting structure Form 80 mm to 130 mm 3 in to 5 in drip loops with the cables FIGURE 21 Creating Cable Drip Loops Earth Grounding the AP CAUTION Make sure that earth grounding is available and that it meets local and national electrical codes For additional lightning protection use lightning rods and lig...

Page 7: ...n the cable itself 2 in Figure 12 2 Attach the safety cable to the AP 3 in Figure 12 FIGURE 24 Attaching the security cable Troubleshooting CAUTION If required you can reset the AP to its factory default settings by pressing the reset button located inside the PoE IN port Use the tip of a pen or a 3mm flat blade screwdriver to press the reset button Press and hold the reset button for 4 seconds to...

Page 8: ... of the bands 5250 5350 MHz and 5650 5850 MHz and that these radars could cause interference and or damageto LE LAN devices Opération dans la bande 5600 5650 MHz n est pas autorisée au Canada Haute puissance radars sont désignés comme utilisateurs principaux c à utilisateurs prioritaires des bandes 5250 5350 MHz et 5650 5850 MHz et que ces radars pourraient causer des interférences et ou des domma...

Page 9: ...d the user shall cease operatingimmediately until no interference is achieved The said legal communications means radio communications is operated in compliance with the Telecommunications Act The low power radio frequency devices must not be susceptible with the interference from legal communications or ISM radio wave radiated devices 限用物質含有情況標示聲明書 設備名稱 無線網路基地台 型號 型式 T750 T750SE Equipment name Ty...

Page 10: ... requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 2014 53 EU Latviski Latvian Ar šo Ruckus Wireless deklarē ka Radio LAN atbilst Direktīvas 2014 53 EU būtiskajām prasībām un citiem ar to saistītajiem noteikumiem Lietuvių Lithuanian Šiuo Ruckus Wireless deklaruoja kad šis Radio LAN atitinka esminius reikalavimus ir kitas 2014 53 EU Direktyvos nuostatas Nederlands...

Page 11: ...e earth the device operates in compliance with FCC rules without any adjustment of output power T750 T750SE Antennas When the device is installed outdoors at an angle above the horizon it may be necessary to reduce output power to insure the energy radiated above 30 from the horizon remains under 21 dBm EIRP Please see table and elevation plots below T750 Omni Antenna 3 4dBi Vertical Polarity Elev...

Reviews: