FIGURE 23 Positioning the Device in the Rack
1.
Screws, 10-32 x 5/8-inch, panhead Phillips
2.
Retainer nuts, 10-32
Four-Post Rack Mount Installation (ICX-RMK-4POST-TL)
Use the following instructions to install the RUCKUS ICX 7550 switch in EIA racks that are between 46 cm and 79 cm (18 inches to 31 inches) using
the four-post flush-mount rack kit included with the switch.
NOTE
Hardware devices illustrated in these procedures are only for reference and may not depict the device you are installing into the rack.
Time and Items Required
Allow 15 to 30 minutes to complete the installation.
The following items are required to install the device using the four-post flush-mount rack kit (ICX-RMK-4POST-TL):
•
#2 Phillips torque screwdriver
•
1/4-inch slotted-blade screwdriver
Parts List
The parts provided in the four-post flush-mount rack kit (ICX-RMK-4POST-TL) are illustrated in the following figure.
Mounting the Device
Four-Post Rack Mount Installation (ICX-RMK-4POST-TL)
RUCKUS ICX 7550 Switch Hardware Installation Guide
Part Number: 53-1005648-04
35
Summary of Contents for RUCKUS ICX 7550
Page 10: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 10 Part Number 53 1005648 04 ...
Page 54: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 54 Part Number 53 1005648 04 ...
Page 66: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 66 Part Number 53 1005648 04 ...
Page 76: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 76 Part Number 53 1005648 04 ...
Page 90: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 90 Part Number 53 1005648 04 ...
Page 102: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 102 Part Number 53 1005648 04 ...
Page 108: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 108 Part Number 53 1005648 04 ...
Page 114: ...RUCKUS ICX 7550 Switch Hardware Installation Guide 114 Part Number 53 1005648 04 ...