4. Commissioning
MF0123A1F
_FCC
_uc
Manual for PSR 700/800 MHz
Page 33
Polarity of cable end
Cable end:
Connect to terminal:
Positive
spade terminal
DCIN+
Negative
spade terminal
DCIN-
Green/Yellow
ring terminal
Ground bolt
table 4-3 Power supply connection (DC)
figure 4-5 DC wires, installed
Notice:
For the installation, observe that a minimum air gap of ¼ inch (6.4 mm) must
be maintained between the local power cable wires and the network/alarm
cables that are pre-installed by the supplier. A good practice is to cut the local
cable to a suitable size so that it will be led directly (without being wound up)
from the opening in the cabinet to the power connectors (DCIN+/DCIN-). In that
way, the air gap can be kept as shown in the example above.
Note:
Observe the applicable national regulations regarding loop impedance,
voltage drop, and methods of installation. Make sure to connect the correct
voltage to the unit.
Note:
Do not install or deinstall the power wires at the POWER terminal blocks while
power is on. Turn off mains power * before connecting the power wires at the
PSR, then, engage mains again.
* Mains power must be interruptible with an external delayed-actions mains breaker. For the mains
breaker use current state-of-the-art material. The following table can be used as reference but
please make sure that your local requirements / local regulations of the AHJ are kept.
Supply source
115 VAC
230 VAC
48 VDC
Inrush current
20 A
40 A
45 A
Nominal current (max.)
1.5 A
0.75 A
3.5 A
Examples for suitable
mains breakers
3 A Class C
2 A Class K
7 A Class C
4 A Class K
8 A Class C
5 A Class K
Network and alarm
cables (pre-installed
by supplier
PSU GND
cable (pre-
installed by
supplier
Example of DC wires of
local power cable (to be
provided by installer)