5. Clean the lip of the inner ring with
lint-free wipe drenched with isopropyl
alcohol.
6. Clean the inside surface of the inner
ring with lint-free wipe drenched with
isopropyl alcohol.
7. Clean the inside of the center
conductor spring tines with a cotton
bud drenched with isopropyl alcohol.
8. Clean in the similar way the
connector of the connected cable.
Remove protective caps from the unit
connector first.