4. Commissioning
Page 16
M0200ABA_ION-U_EU_H_23_23
User’s Manual for ION
®
-U
4. Commissioning
4.1. General
Read and observe chapter 1.2 Health and Safety as well as the description carefully
to avoid mistakes and proceed step by step as described.
•
Do not operate the Extension Unit without terminating the antenna connectors.
The antenna connectors may be terminated by connecting them to their
respective antennas or to a dummy load.
•
Only qualified personnel should carry out the electrical, mechanical,
commissioning, and maintenance activities that require the unit to be powered
on when open.
•
When opening the Extension Unit do not damage the warranty labels on the
internal devices. The warranty is void if the seals are broken.
4.2. High Power EU Mechanical Installation
4.2.1. Health and Safety for mechanical installation
Read and observe chapter 1.2 Health and Safety
.
1. Caution:
Risk of injury by the considerable weight of the unit falling. Ensure there
is adequate manpower to handle the weight of the system.
2.
Caution:
Risk of serious personal injury by equipment falling due to improper
installation. The installer must verify that the supporting surface will safely
support the combined load of the electronic equipment and all attached hardware
and components. The screws and dowels (wall anchors) used should also be
appropriate for the structure of the supporting wall.
4.2.2. Property Damage Warnings for mechanical installation
1. Attention:
Do not install the unit in a way or at a place where the specifications
outlined in the Environmental and Safety Specifications leaflet of the supplier are
not met.
2. Attention:
Due to power dissipation, the Extension Unit may reach a very high
temperature. Ensure sufficient airflow for ventilation.
3. Notice:
Exceeding the specified load limits may cause the loss of warranty.
4. Notice:
When connecting and mounting the cables (RF, expansion, mains, ...)
ensure that no water can penetrate into the unit through these cables.
5. Notice
: Ensure that there is free access to the electrical connections as well as
to the cabinet. The approved bending radius of the connected cables must not be
exceeded. See chapter 7.1 for more details.