3. Commissioning
MF0150A4A.doc
Manual for ION-M7P/17EHP/19P
Page 21
figure 3-7 Pole
mounting - pitches
figure 3-8 Pole
mounting - brackets
figure 3-9 Pole mounting - fasten RU
1. Apply this procedure to both mounting brackets on both sides:
Screw a hexagon nut (E) to the threaded bolt and place a flat washer (F)) on it.
Insert this side of the bolt into the mounting bracket (A). Then, fasten the
mounting bracket with a flat washer (F), split lock washer (G), and the locking nut
(D). See figure 3-6 Pole mounting – with brackets.
2. Place the pre-mounted brackets with threaded bolts to the pole or post, slide the
counter bracket (B) on the threaded bolts and fasten the kit with a flat washer (F),
split lock washer (G), and the locking nut (D).
Note:
When fastening the brackets make sure that they are installed
congruently and not at an angle to each other. To determine the distance
between the clamps refer to figure 3-7 Pole mounting - pitches.
3. Hang the Remote Unit into the upper bracket, insert it into the lower bracket (see
chapter 3.1.3), and fasten it to the lower bracket with the M8x25 screws (H), split
lock washers (G), and flat washers (F).
The diameter of the pole or column must be in the range from 65 to 120 mm (2.6 to
4.7 inch).