Visit www.commscope.com for complete specifications on all the products listed
Bulletin # 7693902 Rev. L
Technical Publication
11
For RRUs 3832, 3936, 3260 and 3268 slide 11 mm conduit inside of power tail
bird resistant sleeve. Replace bird resistant connector by sliding connector
over cable while twisting clockwise. Tighten the gland nut on the power cable.
Power Tail Installation to RRU, Blue -48VDC and Black 0V
After the trunk cable is mounted measure
distance to determine the length of the
bird resistant sleeve and power conductor.
Remove bird resistant connector by loosening the gland
nut. Open the safety clip with a screwdriver. Pull the
connector off the bird resistant sleeve. Push the safety clip
back into the connector.
X
X
2
1
3
4
Cut bird resistant sleeve at . Be
careful not to cut the power conductor
inside of the bird resistant sleeve.
Dispose of excess bird resistant sleeve.
X
X
For RRUs 3832, 3936, 3260 and
3268 cut the power conductor
to 200 mm (7.78 in). Dispose of
excess power conductor.
1
2
1
2
200 mm
(7.78 in)
1
2
4
3
1
2
3
4a
4b
5
For RRUs 3256 and 3929 cut
the power conductor to
125 mm (4.92 in). Dispose of
excess power conductor.
125 mm
(4.92 in)
Remove the jacketing
to expose the blue/
black conductors.
6a