OPERATION
Priming
Priming the pump prepares the motor for safe operation.
1. Ensure the pump is turned off at the mains power.
2. Fully open any shut off mechanisms (e.g: spray nozzle, valves etc.) in the output hose or pipe so
that the air can escape without obstruction.
3. Unscrew the transparent filter cover (2) by turning anti-clockwise (Fig. 12)
and remove the filter (10).
4. Using a hose or other method, into the filter cavity, completely fill the
pump housing (4) with water (Fig. 13).
5. Replace the filter (10) into the filter cavity.
6. Tighten the transparent filter cover (2) securely by turning clockwise.
Note:
Do not operate the pump without the filter (10) installed. Damage caused to internal
components will not be covered under warranty.
7. Open the discharge line and the suction line.
8. Insert the plug into the mains power socket (Fig. 14). Avoid using
extension cords as this can lead to a voltage drop which may cause
power loss and overheating. Once installed in a suitable location, the
mains power can be switched on.
12
Fig. 14
Fig. 12
Fig. 13