Turning the Pump On and Off

9.  Depress the on/off switch (8) to the On (I) position (Fig. 15). The pump

will begin operation, the pump may take several minutes to fully prime

air from the suction line and inside the pump.

Note: 

The pump can be used to perform suction up to 8 metres. This is the maximum suction height

that the pump can operate at. 

Note:

The pump will automatically shut down when the cut-out pressure of 

3 bar is reached. This is displayed on the pressure gauge (7) (Fig. 16).

The pump will only operate when water is drawn at the discharge outlet (1).

At all other times, the pump will cease operation to conserve energy.

When water is used and the pump’s pressure decreases to 1.5 bar the

pump will automatically restart.

10. To turn the pump off, depress the on/off switch (8) to the Off ("O")

position (Fig. 17). 

Storing the Pump

11. Before storing the pump. It is recommended to empty the pressure 

tank (6). Turn the drain screw (5) anti-clockwise and remove from the

pressure tank (6) (Fig. 18). This will drain any excess water. Replace 

the drain screw (5) by turning clockwise.

Note:

Ensure the gate valve on your water tank is not left open as this will

allow water to drain from the water tank.

Fig. 15

Fig. 16

Fig. 17

Fig. 18

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for PPT-800

Page 1: ...00 INSTRUCTION MANUAL 0112 WARNING Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnin...

Page 2: ...or garden watering and washing cars transferring water from tanks ponds and dams and transferring water for domestic irrigation This product is not suitable for use with drinking potable water SPECIFI...

Page 3: ...r Cover 3 Suction Inlet 4 Pump Housing 5 Drain Screw 6 Pressure Tank 7 Pressure Gauge 8 On Off Switch 9 Handles 10 Filter 11 Power Cable not shown 12 Air Valve Cover not shown 13 Air Valve not shown 1...

Page 4: ...TRUCTIONS ADDITIONAL SAFETY INSTRUCTIONS FOR PUMPS SUGGESTED APPLICATIONS PACK CONTENTS FITTINGS AND TOOLS REQUIRED FOR INSTALLATION SET UP INSTALLATION OPERATION HINTS WHEN USING THE PUMP MAINTENANCE...

Page 5: ...hermal protection overload switch The water pump stops if an overload occurs The motor restarts automatically after it has cooled down Using an extension lead Always use an approved extension lead sui...

Page 6: ...e safety equipment Always wear eye protection Safety equipment such as dust mask nonskid safety shoes hard hat or hearing protection used for appropriate conditions will reduce personal injuries c Avo...

Page 7: ...al sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Ch...

Page 8: ...watering and washing cars and boats Transferring water for domestic irrigation CAUTION Not to be used to circulate swimming pool water PACK CONTENTS 1 x Automatic pressure pump PPT 800 1 x Pre filter...

Page 9: ...nected when using the pump Connecting Hose or Pipe to the Suction Inlet 1 Remove the plastic protection cover from the suction inlet 3 Fig 2 Note It is recommended that you use a suction set with suct...

Page 10: ...ose or pipe and impede the priming process see section starting the pump for description on priming the pump Fig 5 7 150mm WATER TANK GATE VALVE NON RETURN VALVE UNION COUPLING SUCTION LINE FIRM BASE...

Page 11: ...s the pump will not run dry Ensure that this is checked when in operation Note A leaking hose or pipe will draw in air and therefore not draw in any water WATER TANK NON RETURN VALVE SUCTION LINE UNIO...

Page 12: ...mum diameter of 19mm 3 4 A smaller diameter output hose or pipe will result in a lower flow rate Note Ensure the output hose or pipe is not restricted in any way and no pressure is obstructing the hos...

Page 13: ...vity completely fill the pump housing 4 with water Fig 13 5 Replace the filter 10 into the filter cavity 6 Tighten the transparent filter cover 2 securely by turning clockwise Note Do not operate the...

Page 14: ...only operate when water is drawn at the discharge outlet 1 At all other times the pump will cease operation to conserve energy When water is used and the pump s pressure decreases to 1 5 bar the pump...

Page 15: ...least 150mm from a solid structure i e wall or fence Running the pump with no water flowing through the pipes will reduce the life of the pump and is not recommended The pump must be turned off at th...

Page 16: ...als are not covered under warranty Cleaning the Pump Housing Use a moist cloth to wipe down the pump housing 4 Allow to dry thoroughly before storing in a dry location that is protected from bad weath...

Page 17: ...let and filter for any foreign matter Pump is not producing enough pressure Check all parts of the pump and clean and check the tank pressure Water source does not have enough water Wait until the wat...

Page 18: ...owing the motor to cool Ensure the pump is in a well ventilated area The motor is faulty or damaged Contact Commercial Electric customer service Poor Performance low pressure flow Faulty suction line...

Page 19: ...ally friendly way Please recycle where facilities exist Check with your local council authority for recycling advice Recycling packaging reduces the need for landfill and raw materials Reuse of recycl...

Page 20: ...T RETURN THE PRODUCT TO YOUR NEAREST BUNNINGS WAREHOUSE WITH YOUR BUNNINGS REGISTER RECEIPT PRIOR TO RETURNING YOUR PRODUCT FOR WARRANTY PLEASE TELEPHONE OUR CUSTOMER SERVICE HELPLINE TO ENSURE A SPEE...

Reviews: