7 HOMEDEPOT.COM
Please contact 1-877-527-0313 for further assistance.
Part
Description
Quantity
AA
I-Beam Bolts, Nuts, Washers
4, 4, 8
BB
I-Beam Clamps
2
CC
I-Beam Shims
2
DD
Motor Attachment Bolts, Nuts, Washers
2, 2, 4
EE
Safety Cable Clamps
2
FF
Blade Bolts, Nuts, Washers
10,10, 20
GG
Safety Retainer Link
5
HH
Guy Wire Clamps
8
SPACING REQUIREMENTS
space from diffuser
space from diffuser
at least 1.5 x diameter away from
intake/discharge
at least 2 x diameter away from intake/discharge
spacing between fans
space
from wall
at least 1.5 x
diameter away
from the wall
at least 3 x diameter of the fans
apart
5
HVAC Diffuser
with airflow
UNDER fan
HVAC Diffuser
with airflow
ABOVE fan
GG
HH
Pre-Installation