GEC 880 Service Manual
Installation
1.2/0111
7
Installation
Components and cabling
Power supply and wall socket
Power supply unit
24 W high-efficiency switched-mode power supply. The power cable must be ordered seperately
Power supply:
PA24W15V
Power Cable:
KAB-C13-AU (Australia)
KAB-C13-EU (Europe)
KAB-C13-UK (Great Britain)
KAB-C13-US (USA)
Please use only DC power supplies with 12 to 18 V sec. and 1.2 A min. The Counter Intercom station is
not qualified for AC supply or DC supply exceeding 18 V.
Wall socket
The operator station must be connected to the wall socket via the supplied cable (CAT6, straight, not
crossed).
The outside loudspeaker, microphone and bell button are connected to the wall socket. Pin assignment
see ”Components and cabling” above.
Attention:
Do not mis-connect the wires of the outside microphone. Polarity must be observed.
However, polarity of the outside loudspeaker is not relevant.
Attention:
If you connect a crossed-out RJ45 cable, irreparable damage to the Intercom station may
occur!
GEC 882
AL10-16
Q400
PA24W15V
KAB-C13-**
Option:
Headset
ASKKAT6-3, 3 m*
Cable length 2.8 m (9.2 ft)
Operator side
Client side
glass, wall, etc.
communication hatch
Cable length 1.5 m (4.9 ft)
wall
socket *
* ...Included in extent of supply
**...Depending on the country-specific
version (AU/EU/UK/US)
LS+
LS–
IN+
AUX+
AUX–
IN–
MIC+
MIC–
1
2
3
4
5
6
7
8
zur GEC 881/
GEC 882
Measurements wall mount box:
88 x 88 x 30 (3.5 x 3.5 x 1.2)
50 (1.97)