Technical Specifications – Standard DC Models
(409A-H4)
Dimensions
(with strobe and ½” mounting spacers) – May vary by model:
Height(Depth)
Length
Width
Retracted
12”
51”
13”
Extended
88”
54”
13”
Recessed installation
14”
60”
20” Minimum
Weight:
160 pounds
Wiring:
Main Power VDC
2/2 SO cord
50’ provided
Control wiring
22/20 PVC Jacketed
50’ provided
Relay protection:
Lights
Cole-Hersey
3055
100
amps
Other electrical
Cole-Hersey 3055 20 amp
Current Draw / Power Requirements:
Average
Generator Requirement
2 x 60 Watt LED
12 VDC - 55 amps
1 kW minimum
2 x 270 Watt LED
Lift actuators and rotation motor will cause higher current draw during use.
Motor Duty Cycle:
(All motors thermally protected, specifications are to thermal relay trip):
Lower stage
1:3 (90 seconds maximum per 5 minute)
Upper stage
1:3 (90 seconds maximum per 5 minute)
Rotation
5-6 Revolutions
Motor Speed:
Lower stage
1.0 inches per minute 12 seconds to full extension
Upper stage
0.5 inches per minute 12 seconds to full extension
Rotation
2.75 RPM at lamp tree
Operation:
Angle of vehicle
10˚ maximum incline
Wind load:
Design maximum
60 mph
Maximum tested
90 mph
Summary of Contents for KL409D
Page 3: ...USER GUIDE 3...
Page 24: ...KNIGHTSLIM 24...
Page 26: ...KNIGHTSLIM 26...
Page 27: ...USER GUIDE 27 Parts List Base...
Page 28: ...KNIGHTSLIM 28 Exploded View Base...
Page 29: ...USER GUIDE 29 Parts List Mid Plate...
Page 30: ...KNIGHTSLIM 30 Exploded View Mid Plate...
Page 31: ...USER GUIDE 31 Parts List Exploded View Lamp Tree...
Page 32: ...KNIGHTSLIM 32 Exploded View Lamp Tree...
Page 33: ...USER GUIDE 33 Parts List Relay Box...
Page 34: ...KNIGHTSLIM 34 Exploded View Relay Box...
Page 35: ...USER GUIDE 35 Wiring Schematics...
Page 36: ...KNIGHTSLIM 36 Holster Box...
Page 37: ...USER GUIDE 37 Holster Box...
Page 38: ...KNIGHTSLIM 38...
Page 39: ...USER GUIDE 39...
Page 40: ...KNIGHTSLIM 40...