background image

Average Latch Retraction Current:  2 Amp

Average Holding Current:  250 mA

High Torque Mode

Average Latch Retraction Current: 900ma

Average Holding Current:  215 mA

Standard Torque Mode

Average Latch Retraction Current: 600 mA

Average Holding Current:  150 mA

Low Torque Mode

Step 1-

 Select your preferred torque mode (ships in standard torque) Press the device push pad to the 

desired setting. (Recommend to fully depress and release 5%, giving the device room for changing door 

conditions.)

Step 2-

  While depressing the push pad, apply power. (i.e. presenting the credential to the reader).

Step 3-

Continue to keep pad depressed, the device will beep 6 times. After the beeps have stopped, release the pad 

and now the adjustment is  complete. If not to your liking repeat the 3 steps. 

Setting PTS

2 Beeps

3 Beeps

5 Beeps

6 Beeps

Beeps

Explanation

Solution

Over Voltage

Under Voltage

Retraction or dogging failure

PUSH TO SET

> 30V unit will shut down. Check voltage & adjust to 24 V.

< 20V unit will shut down. Check voltage & adjust to 24 V. 

After 1st fail: 5 beeps then immediately attempts to retract again.

After 2nd fail: 5 beeps with pause in-between for 30 seconds then device 

attempts to retract again.

After 3rd fail: 5 beeps every 7 minutes, device will not attempt to retract.

 

To Reset: Depress bar for 5 seconds at any time.

Device is recording it’s new position and power mode after the 6th beep.

Troubleshooting & Diagnostics

4 Beeps

Failed Sensor

Verify all 3 sensor wires are installed correctly. Replace sensor if problem persists 
by contacting office.

**Important Info**

Make sure to set PTS before finishing installation

Technical Information

mm4s switches

on

on

on

on

off

LOW TORQUE

STANDARD TORQUE

HIGH TORQUE

PTS PROGRAMMING LOCKED

off

off

off

SPECIFICATIONS

•  Input Voltage:   24VDC +/- 10%
•  Wire gauge:  Minimum 18 gauge
•  Direct wire run - no relays or 

access control units in-between 
power supply & module

U S   C U S T O M E R   S U P P O R T 1 - 8 8 8 - 6 2 2 - 2 3 7 7   |   W W W . C O M M A N D A C C E S S . C O M   |   C A   C U S T O M E R   S U P P O R T   1 - 8 5 5 - 8 2 3 - 3 0 0 2

MM4s V

Ideo

Summary of Contents for MLP-UL-M KIT

Page 1: ...dule 2 8 32 X 1 4 Phillips head screws 1 8 Lead w VD Connector 1 Push go connector 1 MM4S switch program sticker 1 Dogging Hole Cap Cordless Drill Hammer Pin Punch recommend or 3 16 drill bit 5 16 Nut driver recommended or Flat head screwdriver 2 Phillips head screwdriver C o m m a n d A c c e s s T e c h n o l o g i e s 2 2 9 0 1 L a P a l m a A v e Y o r b a L i n d a C A 9 2 8 8 7 P h o n e 8 8...

Page 2: ...ll shut down Check voltage adjust to 24 V 20V unit will shut down Check voltage adjust to 24 V After 1st fail 5 beeps then immediately attempts to retract again After 2nd fail 5 beeps with pause in between for 30 seconds then device attempts to retract again After 3rd fail 5 beeps every 7 minutes device will not attempt to retract To Reset Depress bar for 5 seconds at any time Device is recording ...

Page 3: ... Command Access power supplies at our factory For more information click here or go to our website U S C U S T O M E R S U P P O R T 1 8 8 8 6 2 2 2 3 7 7 W W W C O M M A N D A C C E S S C O M C A C U S T O M E R S U P P O R T 1 8 5 5 8 2 3 3 0 0 2 Retrofit 2 pin Connector The new 2 pin connector is used when retrofitting a older Command or Von Duprin installation so you can plug in to the exisiti...

Page 4: ... Installation Instructions Continue sliding push pad half way out of the base rail so activating bracket is accessible Next remove metal rod and AB mount can be put aside Activating Bracket Baserail Metal Rod AB Mount U S C U S T O M E R S U P P O R T 1 8 8 8 6 2 2 2 3 7 7 W W W C O M M A N D A C C E S S C O M C A C U S T O M E R S U P P O R T 1 8 5 5 8 2 3 3 0 0 2 ...

Page 5: ...ded 7 Re install metal rod securing activating bracket to motor mount 8 9 Slide push pad with motor kit back into the device Also the filler plate must be slid in at same time Make sure Latch retractor is pressed down so push pad slides over it U S C U S T O M E R S U P P O R T 1 8 8 8 6 2 2 2 3 7 7 W W W C O M M A N D A C C E S S C O M C A C U S T O M E R S U P P O R T 1 8 5 5 8 2 3 3 0 0 2 CONTI...

Page 6: ...ly depress and release 5 giving the device room for changing door conditions Step 2 While depressing the push pad apply power i e presenting the credential to the reader Step 3 Continue to keep pad depressed the device will beep 6 times After the beeps have stopped release the pad and now the adjustment is complete If not to your liking repeat the three steps Step 4 Once you found the correct loca...

Reviews: