Specifications

Troubleshooting & Diagnostics

•  Operating Voltage Range: 24 VDC +/- 10%

•  Hold Current: 260 mA @ 24 VDC

•  Surge Current: 1.6 A for 350 ms @ 24 VDC

•  Peak Current: 7 A @ 24 VDC

•  Input wires to PM300 : Non-polarized Black (+)(-)

•  Output wire from PM300: Yellow=Pull Coil; Orange= Hold 

Coil;  Green=Common

Power Supply for PM300 and PM300D in High Output Mode:

In High Output mode, the PM300 is designed for & MUST BE 

powered by the Command Access PS1, PS5-4, or PS5-6 power 

supplies only. 

Wire Run Guidelines: 

For best results we recommend that your maximum wire run not exceed the following: 

                              18ga.= 700’               16ga. = 1000’                  14ga. = 1250’                  12ga. = 1500’. 

 

Latch Retraction

Lever Control

•  Operating Voltage Range: 

Switches

•  REX: 

Green - Common (C)

Blue - Normally Open (NO)

Gray - Normally Closed (NC)

Green/Black - Common (C)

Blue/Black - Normally Open (NO)

Gray/Black - Normally Closed (NC)

•  LBM: 

• 

Check the Module is on High Output.

• 

Confirm that power supply is a Command Access PS1, PS5-4, or PS5-6

24VAC/DC 350mA 

12VAC/DC 700mA 