User Manual
SW-81VA-2
COMM-TEC GMBH
SIEMENSSTRASSE 14
T49(0)7161/3000-0
WWW.COMM-TEC.DE
D-73066 UHINGEN
T49(0)7161/3000-333
8.0 RS-232 Control and Commands
All functions of the SW-81VA-2 can be controlled with external controllers like
computers or third party controllers (e.g. AMX, RTI). A serial controller is any device
that is connected to the standard RS-232 serial port (25pin SubD female) on the
rear panel and that can send and receive ASCII character format.
Fixed settings for serial communication with the SW-81VA-2 are:
Tx must be connected to pin # 12 of the 25pin
SubD female REMOTE connector.
Ground is pin # 25.
In the table the hex commands and their dedicated functions are listed in order to
control the SW-81VA-2 by RS-232 (Input 9 to 29 for CASCADE function).
Hex
Command Function
Hex
Command Function
Hex
Command Function
31h
Input 1
3Bh
Input 11
45h
Input 21
32h
Input 2
3Ch
Input 12
46h
Input 22
33h
Input 3
3Dh
Input 13
47h
Input 23
34h
Input 4
3Eh
Input 14
48h
Input 24
35h
Input 5
3Fh
Input 15
49h
Input 25
36h
Input 6
40h
Input 16
4Ah
Input 26
37h
Input 7
41h
Input 17
4Bh
Input 27
38h
Input 8
42h
Input 18
4Ch
Input 28
39h
Input 9
43h
Input 19
4Dh
Input 29
3Ah
Input 10
44h
Input 20
Baud Rate
9600
Data Bits
8
Stop bit
1
Parity
None
Hex
Command
Function
Note
52h
Autosequence
effective only for single unit
53h
Autoswitching
effective for single and cascaded unit(s)
54h
Mute Video only
effective for single and cascaded unit(s)
55h
Mute Audio only
effective for single and cascaded unit(s)
56h
Mute Video + Audio