4K HDBaseT 4x4 Matrix Switcher
a.
Y = 1~4, send this command to the
corresponding HDBaseT receiver to
control far-end device.
b.
Y = 5, send this command to all
HDBaseT receivers to control all
far-end devices.
c.
Y = A, B, C, or D
d.
Y = E, F, G, or H
For items c or d, send this command,
it will be saved to the matrix switcher
but taken without action to
corresponding HDBaseT receiver.
And its command function will be
effective almost at the same time
when you send the command PWON
(for item c) or PWOFF (for item d).
Note:
A & E are for port 1. B & F are for
port 2.
C & G are for port 3. D & H are for
port 4.
2
X is for baud rate, its value ranges
from 1 to 7 (1--2400, 2--4800,
3--9600, 4--19200, 5--38400,
6—57600, 7--115200)
3
***** is for data (max 48 Byte)
EDIDH[x]B[y].
Input port [y] learns the EDID from output
port [x].
If the EDID data is available and the
audio part supports not only PCM mode,
then force-set it to support PCM mode
only. If the EDID data is not available,
then set it as initialized EDID data.
EDIDH[x]B[y]
EDIDPCM[x].
Set the audio part of input port [x] to
PCM format in EDID database.
EDIDPCM[x]
EDIDG[x].
Get EDID data from output [x] and
display the output port number.
Hexadecimal
EDID
data and carriage
return character
EDIDMInit.
Restore the factory default EDID data of
every input.
EDIDMInit.
EDIDM[X]B[Y].
Manually
EDID
switching.
Enable
input[Y] to learn the EDID data of
output[X]. If the EDID data is not
available, then set it as initialized EDID
data.
EDIDM[X]B[Y]
EDIDUpgrade
[x].
Upgrade EDID data via the RS232 port.
Please
send
the
EDID file
Comm-tec Srl
26
www.comm-tec.it