GMT 125 - 15/15 FUSE PANEL
SETUP AND OPERATION MANUAL
PAGE 8 - INSTALLATION
4.8 Installing the Network Cable
(016-2102-10 and 016-
2106-10 Models Only)
An ethernet module is available on models with per-channel current monitoring.
If remote monitoring over the network is required, complete the following steps to
connect the Ethernet module with embedded web server.
OTEE:
For initial configuration, it is recommended to use a crossover Cat 5/5e/6 UTP cable
to connect a laptop directly to the Ethernet port of the GMT panel. If the laptop is configured
for Auto MDI-X, a straight-through cable may be used.
Step 1.
Connect a Cat 5/5e/6 UTP Ethernet cable from the local network to the
Ethernet port on the rear of the panel. Refer to "Appendix A: Mechanical
Drawings" on Page 13 for exact location. Use a TIA/EIA T-568B pinout for the
network connection.
Step 2.
For information on configuring the web server, see "5.2 Review System Status
via the Embedded Web server" on Page 9.
4.9 Installation Checklist
y
Rack mount ears configured for 19/23 in.
y
Ears mounted to panel and rack securely
y
Input power cables/lug and return cables/lugs securely bolted/connected to rear
of panel
y
Heat shrink installed on cables
y
Fuse fail alarm contacts wired to remote monitoring device
(if required)
y
Fused outputs wired with correct polarity, crimp lugs, wire lacing, or cable tie
routing to equipment loads
y
Output connections secured
y
Fuses sized as required for each load
y
All safety covers attached
Figure 15. Ethernet Module
Summary of Contents for GMT 125-15A
Page 1: ...SETUP AND OPERATION MANUAL F O R T E L E C O M B R O A D B A N D GMT 125 15A 15B Fuse Panel...
Page 3: ...SETUP AND OPERATION MANUAL F O R T E L E C O M B R O A D B A N D GMT 125 15A 15B Fuse Panel...
Page 6: ...GMT 125 15 15 FUSE PANEL SETUP AND OPERATION MANUAL PAGE vi THIS PAGE INTENTIONALLY LEFT BLANK...
Page 24: ...GMT 125 15 15 FUSE PANEL SETUP AND OPERATION MANUAL PAGE 18 NOTES...