ComfortNet™ Communicating Thermostat
7
69-2687EFS—01
These default Energy Saver settings can reduce expenses by as much as 33%. (See
next page to customize each time period.)
Energy Saver settings for maximum cost savings
Wake
6:00
am
70°
78°
70°
78°
Leave
8:00
am
62°
85°
62°
85°
Return
6:00
pm
70°
78°
70°
78°
Sleep
10:00
pm
62°
82°
62°
82°
Cool
(Mon-Fri)
Start time
Heat
(Mon-Fri)
Period
Heat
(Sat-Sun)
Cool
(Sat-Sun)
Residential Use
Occupied 1
8:00
am
70°
75°
On
Unoccupied 1
10:00
pm
55°
85°
Auto
Occupied 2*
12:00
am
70°
75°
On
Unoccupied 2*
12:00
am
55°
85°
Auto
Cool
Start time
Heat
Period Fan
Commer
cial Use
0ERIODISCANCELLEDBYDEFAULT)FYOUACTIVATEITTHEVALUESSHOWNABOVEAREDEFAULTSETTINGS
Operating Manual
8
69-2687EFS—01
MENU
MCR32965
MCR32966
Create/Edit Schedule
Guide me through
scheduling
MCR32967
To adjust program schedules
Press
MENU,
then
CREATE/EDIT
SCHEDULE
to display options:
p
Guide me:
This option creates a
schedule for you, by asking simple
questions.
p
I’ll do it myself:
This is a faster way
to create a schedule manually.
p
View/Edit:
This displays the full
schedule, so you can make quick
adjustments.
Press
CREATE/EDIT SCHEDULE
Press any displayed option
Press
HELP
ATANYMENUSCREENFORMORE
INFORMATIONABOUTSCHEDULEOPTIONS
To reduce costs, you should use the pre-set
Energy Saver settings (see page 7).
Press
MENU
ComfortNet™ Communicating Thermostat
9
69-2687EFS—01
Cancel
Hold
Done
MCR32968
Program schedule override: residential use
Press
V
or
W
to change the tempera-
ture. It will be maintained until the “hold”
time you set.
Press the
PERMANENT HOLD
button to
keep the same temperature until you
manually change it or resume the
program schedule.
To cancel these settings at any time,
press
CANCEL HOLD.
Press to change temperature
Press to set
“hold” time
Press to
cancel
“hold”
Press to
begin “hold”
Operating Manual
10
69-2687EFS—01
Cancel
Hold
Done
MCR32970
MCR32969
OVERRIDE
Program schedule override: commercial use
Press
V
or
W
to change the
temperature. It will be maintained until
the “hold” time you set.
Press
OVERRIDE
to use a pre-set
“occupied” temperature if a person is
present during an unoccupied period.
The new temperature will be maintained
for at least 1 hour, and can be adjusted
up to the maximum time set by the
installer. To change the time, press the
HOLD UNTIL
arrow buttons.
The programmed schedule will resume
when the override timer expires. To
cancel the override at any time, press
CANCEL HOLD.
Press to change temperature
Press to set
“hold” time
Press to
cancel
“hold”
Press to
begin “hold”
Press to activate “occupied” mode