8
INSTALLATION
& USE
www.comfortcompany.com
INSTALLATION (ACTA-RELIEF™ POWER)
For Acta-Relief
™
& Acta-Relief
™
LTS using Compass
®
Power Mount Hardware. All tools needed are provided.
C
F
G
D
D
E
E
H
A
1
4
5
2
3
B
1
Start by turning knob
A
counterclockwise.
2
Remove hardware shaft
C
from mounting bracket
B
and set
aside.
3
Loosen bolts
D
with
⅛
” allen wrench and remove along with
washers
E
and spacer plate
F
from mounting bracket
B
.
Do
not use
spacer plate
F
with Acta-Relief™ with Compass
®
Power Mount so either discard or retain for future use.
4
Align mounting bracket
B
with desired head support holes
on power mount bracket
G
. Note: If needed, partially remove
back support cover (not pictured) allowing additional access
to head support holes on mounting bracket
G
from the front.
5
Attach
B
with bolts
D
, washers
E
, and additional thick wash-
ers
H
provided from the inner face of power mount bracket
G
and tighten to 65 lb-in. Replace and secure back support
cover if it was removed.
6
Insert hardware shaft
C
into mounting bracket
B
and turn
knob
A
clockwise to secure. Note: Make sure at least
½
” of
shaft
C
is completely through the bottom of
B
at all times (see
page 7, figure 2.5). See pages
15-17 f
or final adjustments.
Figure 2.6
Figure 2.7
Note: Head support pad is not shown but in most
cases will come attached to hardware. See page
14 for instructions on attaching head support pad.
Instructions for adding a link on pages 12-13.