GFCI (120 volt units only)
Th e GFCI, or Ground Fault Circuit Interrupt, fi tting on the power pack
electrical cord should be tested monthly. Th ere are no user serviceable parts
inside the GFCI. Do not open the GFCI as this will void your warranty.
To test the GFCI, use the following procedure.
If the GFCI device does not function properly, do not use your
spa. Call the dealer or factory immediately for instructions. Do
not bypass the GFCI device.
1. Turn on the turbo wave blower.
2. Push the test button on the GFCI located
at the end of the power cord. Th e GFCI
light should go out and the turbo wave
blower should shut off . If the GFCI light
does not go out, and the turbo wave
blower does not shut off , the GFCI is
faulty. Do not use the spa. Immediately
contact your dealer or the factory for
instructions.
3. Press the reset button on the GFCI. Th e
light on the GFCI should turn on. If the
GFCI light does not turn on the GFCI is
faulty. Do not use the spa. Immediately
contact your dealer or the factory for instructions.
Light
Test
Reset