SERVICE HINTS

When Gas Pressure Is Too Low

•  pilot will not stay lit
•  burners will have delayed ignition
•  heater will not produce specified heat
•  propane/LP gas supply may be low
You may feel your gas pressure is too low. If so, con-

tact your local natural or propane/LP gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, 

operation or troubleshooting. If so, contact DESA 

Heating Productsʼ Technical Service Department at 

1-866-672-6040. When calling, please have your 

model and serial numbers of your heater ready.
You can also visit DESA Heating Productsʼ techni-

cal service web site at 

www.desatech.com

.

REPLACEMENT PARTS

Note:

 Use only original replacement parts. This 

will  protect  your  warranty  coverage  for  parts 

replaced under warranty. 

PARTS UNDER WARRANTY

Contact  authorized  dealers  of  this  product.  If 

they canʼt supply original replacement part(s), 

call DESA Heating Productsʼ Technical Service 

Department at 1-866-672-6040.
When  calling  DESA  Heating  Products,  have 

ready
•  your name
•  your address
•  model and serial numbers of your heater 
•  how heater was malfunctioning
•  type of gas used (propane/LP or natural gas)
•  purchase date
Usually, we will ask you to return the part to the 

factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they 

canʼt supply original replacement part(s), either 

contact your nearest Parts Central (see page 26) or 

call DESA Heating Products at 1-866-672-6040 for 

referral information.
When  calling  DESA  Heating  Products,  have 

ready
•  model number of your heater 
•  the replacement part number

ACCESSORIES

Purchase these heater accessories from your local 

dealer. If they can not supply these accessories, 

call DESA Heating Products at 1-866-672-6040 

for referral information. You can also write to the 

address listed on the back page of this manual.

EQUIPMENT SHUTOFF VALVE 
GA5010

For all models.

 Equipment shutoff valve with 1/8" 

NPT tap. Fits 1/2" NPT pipe.

CLEANING KIT - CCK 
(Not Shown)

For all models.

 Your vent-free gas appliance re-

quires regular cleaning and maintenance to prevent 

performance problems. This kit gives you the tools 

and instructions to make it easy to clean all critical 

areas of your appliance.

INFORMATION VIDEO - 108917-01

For all models.

 A care and maintenance video is 

available by calling 1-866-672-6040.

SPECIFICATIONS

   

SL30PT 

SL30NT

Btu (Variable) 

16,000/30,000 

16,000/30,000

Type Gas  

Propane/LP Only 

Natural Gas Oly

Ignition 

Piezo 

Piezo

Pressure Manifold  

8" W.C. 

3.5" W.C.

Inlet Gas Pressure (in. of water)

  Maximum 

14" 

10.5"

  Minimum* 

11"  

5"

Shipping Weight  

28 lbs. 

28 lbs.

* For input adjustment

Summary of Contents for (VENT-FREE) GAS STOVE HEATER

Page 1: ...electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the re de...

Page 2: ...the rating plate This appliance is not convert ible for use with other gases Aftermarket Completion of sale not for purpose of resale from the manufacturer State of Massachusetts The installation mus...

Page 3: ...ols can be dangerous WARNING Donotallowfans to blow directly into the stove Avoidanydraftsthatalterburner ame patterns Ceiling fans can create drafts that alter burner ame patterns Altered burner patt...

Page 4: ...ion page 5 If heater keeps shutting off see Troubleshooting page 18 12 Do not run heater where ammable liquids or vapors are used or stored under dusty conditions 13 Do not use this stove to cook food...

Page 5: ...oper combustion and ventilation Exhaust fans replaces clothes dryers and fuel burning appliances draw air from the house to operate You must provide adequate fresh air for these appliances This will i...

Page 6: ...lume of space x 20 maximum Btu Hr the space can support Example 2560 cu ft volume of space x 20 51 200 maximum Btu Hr the space can support AIR FOR COMBUSTION AND VENTILATION Continued 3 Add the Btu H...

Page 7: ...your pri mary heat source If you have a centralheatingsystem youmay run system s circulating blower whileusingheater Thiswillhelp circulatetheheatthroughoutthe house In the event of a power outage yo...

Page 8: ...G This appliance is equipped for natural or pro pane LP gas Field conversion is not permitted INSTALLATION Continued CLEARANCES TO COMBUSTIBLES Vent Free Operation Only WARNING Maintain the minimum cl...

Page 9: ...avoidscratching stove edges INSTALLATION Continued Figure 5 Removing Back Panel Bolt Product Identi cation Label Back Stove Panel Figure 6 Laying Down Stove On Side Stove Style May Vary Depending on M...

Page 10: ...olt stop and the bottom nut is for door leveling adjustment 12 Check general catch bolt alignment with door claw Make nal adjustment and door leveling after stove is in normal standing position 13 Car...

Page 11: ...through stove bottom Connect hex nut to bolt on underside of stove bottom The bolt hex head is for a 5 16 socket and the hex nuts are for a 3 8 socket If sockets are not available use adjustable wrenc...

Page 12: ...uge connection Purchase the optional CSA design certi ed equipment shutoff valve from your dealer See Accessories page 21 Figure 17 Gas Regulator Location and Gas Line Access Into Stove Cabinet Back S...

Page 13: ...lator Natural From Gas Meter 5 W C to 10 5 W C Pressure CSA Design Certi ed Equipment Shutoff Valve With 1 8 NPT Tap Approved Flexible Gas Hose if allowed by local codes We recommend that you install...

Page 14: ...igure 20 2 Pressurize supply piping system by either opening propane LP supply tank valve for propane LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed...

Page 15: ...ou do not fol low these instructions exactly a re or explosion may result causing property damage per sonal injury or loss of life A This appliance has a pilot which must be lighted by hand When light...

Page 16: ...odulating down in most cases MANUAL LIGHTING PROCEDURE 1 Follow steps 1 through 5 under Lighting Instructions page 15 2 Depress control knob and light pilot with match 3 Keep control knob pressed in f...

Page 17: ...se follow the directions on the can If you don t follow directions on the can you could damage the pilot assembly Note Removing the rear panel and top grates of your stove will make cleaning easier 1...

Page 18: ...ssure B Dirty or partially clogged ODS pilot 5 Thermocouple connection loose at control valve 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pi...

Page 19: ...knobtoLOposition and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local natural or propane LP gas company 3 Observe minimum installation clearances...

Page 20: ...t is partially clogged 1 Gas leak See Warning statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement at top of page OBSER...

Page 21: ...you to return the part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they can t supply original replacement part s either contact your nearest Parts Central see...

Page 22: ...www desatech com 115580 01A 22 ILLUSTRATED PARTS BREAKDOWN SL30PT Shown SL30NT 14 16 3 4 15 5 11 6 12 7 10 15 8 9 1 17 2 18 18 18 13...

Page 23: ...er Tube 1 8 099056 19 099056 26 Burner Ori ce Injector 1 9 111124 01 111124 01 Burner Retainer Spring 1 10 102980 01 102980 01 Burner 1 11 101329 22 101329 21 Control Valve 1 12 104472 01 104472 01 Br...

Page 24: ...www desatech com 115580 01A 24 ILLUSTRATED PARTS BREAKDOWN CISC CISG 7 4 6 4 5 4 5 1 5 2 3 5 3 5 4 2 1R 1C 1L...

Page 25: ...70 01 One Leg Charcoal 4 Total Per Stove 1 104970 02 One Leg Forest Green 4 Total Per Stove 1 5 104971 01 Hardware Kit 1 5 1 Door Hinge Step Bolt With Shoulder 1 Per Unit 1 5 2 Door Catch Bolt M8 x 1...

Page 26: ...ng Green KY 42103 3414 270 846 1199 1 800 654 8534 Fax 1 800 846 0090 franktalk aol com Master Parts Dist 1251 Mound Ave NW Grand Rapids MI 49504 2672 616 791 0505 1 800 446 1446 Fax 616 791 8270 www...

Page 27: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Page 28: ...ed by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXT...

Reviews: