15
104779
OWNER’S MANUAL
INCORRECT FLAME PATTERN
AT HIGH POSITION
CORRECT FLAME PATTERN
AT HIGH POSITION
Good Pilot-Nat. Port
GRH/OV 007D
INSPECTING
BURNER
Check pilot flame pattern and burner flame
pattern often.
PILOT FLAME PATTERN
Figure 25 shows a correct pilot flame pat-
tern. Figure 26 shows an incorrect pilot
flame pattern. The incorrect pilot flame is
not touching the thermocouple. This will
cause the thermocouple to cool. When the
thermocouple cools, the heater will shut
down.
If pilot flame pattern is incorrect, as shown
in Figure 26
• turn heater off (see To Turn Off Gas to
Appliance, page 14)
• see Troubleshooting, pages 16 through 18
Thermocouple
Pilot Burner
Figure 25 - Correct Pilot Flame Pattern
Bad Pilot-Nat. Port
GRH/OV 007E
Pilot Burner
Thermocouple
Figure 26 - Incorrect Pilot Flame Pattern
BURNER FLAME PATTERN
Figure 27 shows a correct burner flame
pattern. Figure 28 shows an incorrect burner
flame pattern. The incorrect burner flame
pattern shows yellow tipping of the flame. It
also shows the flame higher than one inch
above the log.
Note:
When using the heater the first time,
the flame will be yellow for approximately
one hour until the log cures.
NOTICE: Do not mistake orange
flames with yellow tipping. Dirt
or other fine particles enter the
heater and burn causing brief
patches of orange flame.
If burner flame pattern is incorrect, as shown
in Figure 28
• turn heater off (see To Turn Off Gas to
Appliance, page 14)
• see Troubleshooting, pages 16 through 18
Yellow Tipping
Figure 27 - Correct Burner Flame Pattern
Figure 28 - Incorrect Burner Flame Pattern
Top of Flame About
One Inch Above Logs
WARNING: If yellow tipping
occurs, your heater could pro-
duce increased levels of carbon
monoxide. If burner flame pat-
tern shows yellow tipping, follow
instructions at bottom of this
page.
CLEANING AND
MAINTENANCE
ODS/PILOT AND BURNER
• Use a vacuum cleaner, pressurized air,
or small, soft bristled brush to clean.
CABINET
Air Passageways
• Use a vacuum cleaner or pressurized air
to clean.
Exterior
• Use a soft cloth dampened with a mild
soap and water mixture. Wipe the cabi-
net to remove dust.
CAUTION: You must keep
control areas, burner, and circu-
lating air passageways of heater
clean. Inspect these areas of
heater before each use. Have
heater inspected yearly by a quali-
fied service person. Heater may
need more frequent cleaning due
to excessive lint from carpeting,
pet hair, etc.
WARNING: Turn off heater
and let cool before cleaning.