13
14
TROUBLESHOOTING (continued)
Problem
Possible Cause
What To Do
Gas odor even when control knob is
in OFF position.
1. Gas leaks. Refer to front of page
Warnings.
2. Gas control defective.
1. Locate and correct leaks immediately.
2. Replace gas control
Gas odor during combustion.
1. Foreign matter in gas or on burner ports.
2. Heater burning vapors form paint,
impurities in air.
3. Gas leaks, refer to front page Warnings
1. Check gas passage way and burner.
2. Ventilate room, stop storing and using
odor causing products near heater.
3. Locate and correct leaks immediately.
Heater shuts off on ODS.
1. Not enough fresh air is available.
2. Low gas pressure.
3. ODS pilot partially clogged.
1. Open window.
2. Contact gas supplier.
3. Clean the pilot.
PROPANE CONSTRUCTION HEATER
Summary of Contents for GCH480 and
Page 1: ...Wash hands after handling...
Page 5: ......
Page 19: ...Se laver les mains apr s toute manipulation...
Page 23: ......
Page 37: ...L vese las manos despu s de su manipulaci n...
Page 41: ......