![Comfort Glow CGB3924PT Owner'S Operation And Installation Manual Download Page 19](http://html1.mh-extra.com/html/comfort-glow/cgb3924pt/cgb3924pt_owners-operation-and-installation-manual_2641296019.webp)
19
104341
OWNER’S MANUAL
Figure 33 - Control Knob and Ignitor But-
ton Location
5.
Turn control knob counterclockwise
C-clockwise
to the PILOT position.
Press in control knob for five (5) sec-
onds (see above).
Note:
You may be running this
heater for the first time after hook-
ing up to gas supply. If so, the con-
trol knob may need to be pressed in
for 30 seconds or less. This will allow
air to bleed from the gas system.
• If control knob does not pop out
when released, contact a qualified
service person or gas supplier for
repairs.
6.
With control knob pressed in, press
and release ignitor button. This will
light pilot. The pilot is attached to the
front burner. If needed, keep press-
ing ignitor button until pilot lights.
Note:
If pilot does not stay lit, con-
tact a qualified service person or gas
supplier for repairs. Until repairs are
made, light pilot with match. To light
pilot with match, see Manual Light-
ing Procedure.
7.
Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
Note:
If pilot goes out, repeat steps
3 through 7. This heater has a safety
interlock system. Wait one (1) minute
for system to reset before lighting
pilot again.
8.
Turn control knob counterclockwise
C-clockwise
to desired heating level. The
burners should light. Set control
knob to any heat level between HI
and LO.
Figure 34 - Pilot
CAUTION: Do not try to adjust
heating levels by using the
manual shutoff valve.
LO
HI
OFF
Pilot
Control Knob
Ignitor Button
Thermocouple
Ignitor
Electrode
Pilot Burner
OPERATING
HEATER
Continued
Thermopile
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
1.
Turn control knob clockwise
Clockwise
to the OFF position.
Shutting Off Burners Only (pilot
stays lit)
1.
Turn control knob clockwise
Clockwise
to the PILOT position.
THERMOSTAT
CONTROL
OPERATION
(Thermostat-Controlled
Models Only)
The thermostat control knob can be set to
any comfort level between Hi and Lo. The
thermostat will gradually modulate the
heat output and flame height from higher
to lower settings, or pilot, in order to
maintain the comfort level you select.
The ideal comfort setting will vary by
household depending upon the amount of
space to be heated, the output of the
central heating system, etc.
Note:
Selecting the Hi setting with the
control knob will cause the burner to
remain fully on, without modulating down
in most cases.
1.
Follow steps 1 through 5 under Light-
ing Instructions, pages 18 and 19.
2.
Depress control knob and light pilot
with match.
3.
Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow step 8.
MANUAL LIGHTING
PROCEDURE