23
104386
OWNER’S MANUAL
OPTIONAL
POSITIONING OF
THERMOSTAT
SENSING BULB
For Masonry and Factory-
built Metal Fireplace
If your log set cycles to pilot, but the room
temperature drops to a lower than ideal
comfort level before the log set comes back
on, you may want to reposition the thermo-
stat sensing bulb.
The thermostat sensing bulb is located near
the gas valve assembly on the mounting
bracket. This location allows the thermostat
to keep the room temperature at an ideal
comfort level for most fireplace applica-
tions. For positioning the thermostat sens-
ing bulb elsewhere, an adhesive-backed
mounting clip is available.
Tools needed: 1/4" hex driver or socket
1.
Remove logs. Locate the gas valve as-
sembly and thermostat sensing bulb
(see Figure 39).
2.
With 1/4" hex driver or socket, loosen
the thermostat screw. Carefully slide
the thermostat sensing bulb out of the
retaining clamp (see Figure 41).
Note:
Do not remove the screw. Make
sure you tighten the screw after remov-
ing the thermostat sensing bulb.
IMPORTANT:
Do not force or bend the
thermostat sensing bulb or capillary.
3.
The thermostat sensing bulb may be
located to the lower right front side of
fireplace. Determine location of sens-
ing bulb, but do not mount sensing bulb
until step 5. If you have a masonry fire-
place, see Figure 42 for location. If you
have a factory-built metal fireplace, see
Figure 43 for location. If your fireplace
has glass doors, position sensing bulb
directly behind door gap on right bot-
tom side (see Figure 44).
4.
The mounting clip must be a minimum
of 3" from bottom of fireplace to pre-
vent crimping of capillary. Once you
have decided on a location, clean the
area thoroughly. Remove the paper
backing from the adhesive on back of
mounting clip. Press the clip into the
new location so that the thermostat
sensing bulb will be positioned verti-
cally with the capillary at the bottom
(see Figure 45). Slide the thermostat
sensing bulb into the clip.
IMPORTANT:
Do not crimp capillary.
Thermostat
Sensing Bulb
Figure 39 - Location of Gas Valve Assem-
bly and Thermostat Sensing Bulb
Figure 40 - Adhesive-backed Mounting
Clip
Figure 41 - Removing Thermostat Sens-
ing Bulb
Gas Valve
Assembly
Mounting
Bracket
Thermostat Screw
Retaining
Clamp
Thermostat
Sensing Bulb
Capillary
Adhesive-
backed
Mounting Clip
Figure 42 - Locating Thermostat Sensing
Bulb on Masonry Fireplace
Thermostat
Sensing Bulb
,
,
,
,
Q
Q
Q
Q
¢
¢
¢
¢
Adhesive-
backed
Mounting
Clip
Thermostat
Sensing
Bulb
Figure 43 - Locating Thermostat Sensing
Bulb on Factory-built Metal Fireplace
,
,
,
,
Q
Q
Q
Q
¢
¢
¢
¢
,
Q
¢
,
,
,
,
Q
Q
Q
Q
¢
¢
¢
¢
Adhesive-
backed
Mounting
Clip
Glass Doors
Figure 44 - Installing Thermostat Sensing
Bulb behind Glass Doors
Thermostat
Sensing
Bulb
Capillary
Thermostat
Sensing Bulb
Do Not Crimp
Capillary
Adhesive-
backed
Mounting
Clip
Figure 45 - Positioning the Thermostat
Sensing Bulb in the Vertical Position with
the Capillary at the Bottom