www.desatech.com
111161-01D
12
INSTALLING HEATER BASE
ASSEMBLY
CAUTION: Do not remove
the data plates attached to the
heater base assembly. The data
plates contain important war-
ranty and safety information.
WARNING: You must secure
this heater to fireplace floor. If
not, heater will move when you
adjust controls. Moving heater
may cause a gas leak.
WARNING: If installing in a
sunken fireplace, special care is
needed. You must raise the fire-
place floor to allow access to
heater control panel. This will in-
sure adequate air flow and guard
against sooting and controls be-
ing damaged. Raise fireplace floor
with noncombustible material.
Make sure material is secure.
CAUTION: Do not pick up
heater base assembly by burners.
This could damage heater. Only
handle base assembly by grates.
IMPORTANT:
Make sure the heater burners are level.
If heater is not level, heater will not work properly.
Figure 10 - Attaching Damper Clamp
Damper
Damper
Clamp
Damper
Manufactured Fireplace
Masonry Fireplace
Damper
Clamp
Damper
INSTALLATION
Continued
Installation Items Needed
• hardware package (provided with heater)
• approved flexible gas hose (not provided) (if
allowed by local codes)
• sealant resistant to propane/LP gas, not provided
• electric drill with 3/16" masonry drill bit
Note:
Install optional remote receiver and hand-
held remote kit (see
Accessories
, page 34) before
installing gas log heater. See installation instruc-
tions included with the kit.
1. Apply pipe joint sealant lightly to male threads
of the fitting to be threaded into gas regulator.
Connect approved flexible gas hose to gas
regulator of heater (see Figure 11).
2. Locate masonry screws in hardware package.
3. Position heater base assembly in fireplace.
4. Place logs in their proper positions on heater base.
5. Center heater base and logs front-to-back and
side-to-side in fireplace.
6. Carefully remove logs without moving heater base.
7. Mark screw locations through holes in mount-
ing flanges (see Figure 12). If installing in a
brick-bottom fireplace, mark screw locations
in mortar joint of bricks.
8. Remove heater base from fireplace.
9. Drill holes at marked locations using 3/16"
masonry drill bit.
10. Attach base assembly to fireplace floor using
two masonry screws (in hardware package)
(see Figure 12).
11. Connect to gas supply. See
Connecting To Gas
Supply,
page 13.
Figure 11 - Attaching Flexible Gas Hose
to Heater
Flexible Gas Hose
(if allowed by local codes)
Fitting
Figure 12 - Attaching Base Assembly to
Fireplace Floor
Masonry Screw
Mounting
Flanges