Installation
Instructions
Choosing The Right Location
Recommend Installation
Your installation location should meet the following requirements:
-Make sure that you install your unit on an even surface to minimize noise and
vibration.
-The unit must be installed near a grounded plug, and the Collection Tray Drain
(found on the back of the unit) must be accessible.
-The unit should be located at least 12” from the nearest wall to ensure
proper
air conditioning. The horizontal louver blade should be at least 19.7” away from
obstacles.
-DO NOT cover the Intakes, Outlets or Remote Signal Receptor of the unit, as this
could cause damage to the unit.
50cm
19.7 inch
Energy Rating Information
How to Stay Cool with a New Portable Air Conditioner(For the models comply with the
requirements of Department Of Energy in US)
Because of a new federal test procedure for Portable Air Conditioners, you may notice that the
cooling capacity claims on portable air conditioner packaging are significantly lower than that of
models produced prior to 2017. This is due to changes in the test procedure, not to the portable
air conditioners themselves.
The energy rating and noise information for this unit is based on the standard installation using and un-extended
exhaust duct without window slider adapter (as shown in the installation section of this manual). At the same
time, the unit must operate on the COOL MODE and HIGH FAN SPEED by remote controller.
The unit with
10 feet
extended exhaust duct is running by using 2 exhaust ducts(Diameter:
6 in.
, Length:
60 in.
+
Diameter:
6 in.
, Length:
60 in.
)
.
The Energy rating and noise information for unit with
10 feet
extended
exhaust duct is not assessed.
(For some models)
NOTE
:
We recommend that operating the unit at room temperature below
9
5
°
F
. Since there is a risk that the unit with
10
feet
extended exhaust duct would not work at room temperature above
9
5
°
F
under some extreme
conditions,
such as the lower air intake be blocked for 50%.
MODE
Temperature Range
MODE
Temperature Range
Ambient Temperature Range For Unit Operating
Cool
62-95°F
Dry
Heat(pump heat mode)
Heat(electrical heat mode)
55-95°F
41-86°F
Exhaust Hose Installation
The exhaust hose and
adapter
must be installed or removed in accordance with the usage mode.
For COOL,HEAT(heat pump type) or AUTO mode
exhaust hose
must be installed. For FAN, DRY or
HEAT
(electrical heat type) mode
exhaust hose
must be removed.
86°F