background image

 

Glass Panel Heater

 

Owner’s Manual

5

OPERATION

• 

 

MODE BUTTON:

 There are four modes: LO, HI, 

AUTO, and STANDBY. Press the MODE button 

to scroll through the functions in the following 

sequence:

• 

 

LO → HI →

 AUT

O → S

TANDBY

 

LO

: low-power heating.

 

HI

: high-power heating.

 

AUTO

: In the automatic mode, the desired 

temperature can be set using the TEMP button.

  When the ambient temperature reaches (or 

exceeds) the set temperature, the heater will stop 

heating. When the ambient temperature is below 

the set temperature, the heater automatically 

will switch to HI power to bring the ambient 

temperature up to the set temperature.

  STANDBY

: The unit does not generate any heat 

when in STANDBY mode. All settings are saved 

while in STANDBY mode.

  To exit the STANDBY mode, press the Mode button 

until the desired mode is displayed.

  TEMP

 

BUTTON:

 The temperature setting range is 

41°F to 95°F (5°C to 35°C).To set the temperature, 

press the TEMP button and the LED display will 

show either the default temperature setting value of 

75°F (24°C) or the last set temperature. 

  Press the TEMP button again to set the desired 

temperature value. Once the desired temperature 

is set, the display will show the set temperature for 

5 seconds, then will display the current ambient 

temperature.

POWER

SWITCH

CONTROL

PANEL

LED

DISPLAY

The power switch and control panel are located on 

the right side of the heater enclosure.

The LED display shows in the upper right corner of 

the glass panel on the front of the heater.

AITONS EQUIPMENT

Summary of Contents for IRGPH15B

Page 1: ...Glass Panel Convection Heater Portable or Wall Mount IRGPH15B INSTALLATION OPERATION MANUAL For Indoor Use only AITONS EQUIPMENT Guelph ON N1H 6H9 1 888 744 2911 www aitons com ...

Page 2: ... dimmer or speed controller Unplug the heater from the power source when not in use 2 WARNINGS This electric appliance produces convection heat and failure to READ AND SAVE THESE INSTRUCTIONS WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury or property damage For indoor use only Do not use the heater close to furniture curtains or Do not cov...

Page 3: ...ll the heater where a draft is likely to affect the temperature setting FIXED WALL MOUNT OPTION INSTALLATION INSTALL ON THE WALL STEP 1 STEP 2 STEP 3 STEP 4 FIXED WALL MOUNT LOCATION Refer to directions on following page FIG 1 MINIMUM CLEARANCES 18 450mm 10 250mm 6 150mm AITONS EQUIPMENT Glass Panel Heater Owner s Manual ...

Page 4: ...ot provided 7 Hold the heater in the upright vertical position and position the top of heater against the wall bracket Push the bottom slots on the heater s back enclosure onto bottom tabs on the vertical bracket bars Pull up on the heater to seat the heater onto the bracket 8 Push the heater toward the top of the bracket s the top slots on the back of the heater enclosure Tighten the 2 screws on ...

Page 5: ... heat when in STANDBY mode All settings are saved while in STANDBY mode To exit the STANDBY mode press the Mode button until the desired mode is displayed TEMP BUTTON The temperature setting range is 41 F to 95 F 5 C to 35 C To set the temperature press the TEMP button and the LED display will show either the default temperature setting value of 75 F 24 C or the last set temperature Press the TEMP...

Page 6: ... show the TIMER OFF setting for 5 seconds and then display the ambient temperature When the timer setting expires the heater will automatically stop heating if the timer is set for 3hr for instance the heater will turn off after operating for three hours TIMER ON button In standby mode the TIMER ON button is used to set a time delay for the unit to start heating The time range is 1hr to 24hr in 1 ...

Page 7: ...proof the express warranty begins on the date of shipment from the factory REMEDY PROVIDED BY THE LIMITED EXPRESS WARRANTY The sole remedy under the Limited Warranty is replacement of the unit If for any reason the replacement product is no longer available during the warranty period Heat Controller shall have the right to allow a credit in the amount of the current suggested retail price of the p...

Page 8: ...subject to change without notice 07 2013 AITONS EQUIPMENT Guelph ON N1H 6H9 1 888 744 2911 www aitons com ...

Reviews: