background image

Owner’s Manual 

Glass Panel Heater

 

4

ELECTRICAL CONNECTION

PORTABLE FLOOR MOUNT OPTION–INSTALL SUPPORT FEET

1.  The wall brackets supplied with the heater must be 

used for the wall mount option

2. The heater should be positioned observing the 

minimum clearances stated around the heater:

     MINIMUM CLEARANCES (SEE FIG 1) :
    From top surface of heater  

18” (450mm)

    From side of heater      

10” (250mm)

    From bottom of heater    

   6” (150mm)

  Do not locate the heater where a draft may affect 

the ambient temperature readings, and thus the 

controll setting.

3.  First remove the wall bracket from the rear housing 

of the heater. Unscrew the (2) screws located on 

the top of the two vertical bars of the wall bracket 

(see Step1 on page 3).

4. 

upper tabs slotted into the rear housing (Step 2).

5.  Slide the wall bracket down to remove it from the 

rear housing (Step 3).

6.  Fix the wall bracket securely to the wall through 

the (4) screw holes provided. Use wall anchors if 

necessary (not provided).

7

.

  Hold the heater in the upright (vertical) position. 

and position the top of heater against the wall 

bracket. Push the bottom slots on the heater’s 

back enclosure onto bottom tabs on the vertical 

bracket bars. Pull up on the heater to seat the 

heater onto the bracket.

8. Push the heater toward the top of the bracket’s 

the top slots on the back of the heater enclosure. 

Tighten the (2) screws on the top of the bracket’s 

vertical bars to lock the heater to the mounting 

bracket (Step 4).

FIXED WALL MOUNT OPTION–INSTALLATION

1. Turn the heater upside down begin assembly of the 

two support feet by unscrewing the wing-nuts. 

2.  Position the support feet with the longer section at 

the rear of the heater as shown (Fig.1-2)..

3. Reinstall the wing nuts and  be sure both wing-nuts 

secure. 

4. Turn the heater upright before operating it.

 

• 

  The heater must be powered with 120V 60Hz 

single phase current.

  The power outlet must be properly polarized and 

grounded. Use of a ground fault circuit interrupter 

(GFCI) is always recommended

• 

  The proper electrical outlet, circuit breaker, etc., 

  Use of an extension cord is not recommended.

 

REAR

AITONS EQUIPMENT

Summary of Contents for IRGPH15B

Page 1: ...Glass Panel Convection Heater Portable or Wall Mount IRGPH15B INSTALLATION OPERATION MANUAL For Indoor Use only AITONS EQUIPMENT Guelph ON N1H 6H9 1 888 744 2911 www aitons com ...

Page 2: ... dimmer or speed controller Unplug the heater from the power source when not in use 2 WARNINGS This electric appliance produces convection heat and failure to READ AND SAVE THESE INSTRUCTIONS WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury or property damage For indoor use only Do not use the heater close to furniture curtains or Do not cov...

Page 3: ...ll the heater where a draft is likely to affect the temperature setting FIXED WALL MOUNT OPTION INSTALLATION INSTALL ON THE WALL STEP 1 STEP 2 STEP 3 STEP 4 FIXED WALL MOUNT LOCATION Refer to directions on following page FIG 1 MINIMUM CLEARANCES 18 450mm 10 250mm 6 150mm AITONS EQUIPMENT Glass Panel Heater Owner s Manual ...

Page 4: ...ot provided 7 Hold the heater in the upright vertical position and position the top of heater against the wall bracket Push the bottom slots on the heater s back enclosure onto bottom tabs on the vertical bracket bars Pull up on the heater to seat the heater onto the bracket 8 Push the heater toward the top of the bracket s the top slots on the back of the heater enclosure Tighten the 2 screws on ...

Page 5: ... heat when in STANDBY mode All settings are saved while in STANDBY mode To exit the STANDBY mode press the Mode button until the desired mode is displayed TEMP BUTTON The temperature setting range is 41 F to 95 F 5 C to 35 C To set the temperature press the TEMP button and the LED display will show either the default temperature setting value of 75 F 24 C or the last set temperature Press the TEMP...

Page 6: ... show the TIMER OFF setting for 5 seconds and then display the ambient temperature When the timer setting expires the heater will automatically stop heating if the timer is set for 3hr for instance the heater will turn off after operating for three hours TIMER ON button In standby mode the TIMER ON button is used to set a time delay for the unit to start heating The time range is 1hr to 24hr in 1 ...

Page 7: ...proof the express warranty begins on the date of shipment from the factory REMEDY PROVIDED BY THE LIMITED EXPRESS WARRANTY The sole remedy under the Limited Warranty is replacement of the unit If for any reason the replacement product is no longer available during the warranty period Heat Controller shall have the right to allow a credit in the amount of the current suggested retail price of the p...

Page 8: ...subject to change without notice 07 2013 AITONS EQUIPMENT Guelph ON N1H 6H9 1 888 744 2911 www aitons com ...

Reviews: