Storing conditions:
Temperature from -30 to +80 °C, humidity from 0 to 100 %RH without
condensation
Material of the case:
ABS
Dimensions:
see dimension drawing
Weight:
P0120 approx. 120 g, P01x2 approx. 140 g, P41x1 approx. 125 g
Liquidation:
Device itself (after its life) is necessary to liquidate ecologically!
Temperature probe P0120
Temperature transducers P41x1
Temperature probe P0102, P0122 and P0132
the stem is situated
in the centre of device
Installation:
Described devices are supplied from external power source by a cable. The cable is used for
transmission of measurement temperature to sensing device too. It is recommended to use shielding
copper cable (e.g. SYKFY) and the shielding connect to ground terminal of sensing side. Outside
diameter of the cable must be from 4 to 8 mm, maximal cross-section area 2.5 mm
2
and maximal
length 1200m. The cable must be located at indoor rooms (probe is not protected for outdoor use).
The cable should not be led in parallel along power cabling. Safety distance is up to 0.5 m otherwise
undesirable induction of interference signals can appear.