![Comet Spa DSG-6 DP Instruction Manual Download Page 21](http://html1.mh-extra.com/html/comet-spa/dsg-6-dp/dsg-6-dp_instruction-manual_2640739021.webp)
vironment should be kept at between 10°C and
35°C.
>
POSITIONING OF THE CHIMNEY FOR
INDOOR APPLICATION
(see fig.
K
)
WARNING: In case of operation indoors,
adequate ventilation and gas venting must be
assured.
Sometimes a chimney is necessary to remove the
exhaustsfrom the pressure cleaner.
This problem hasn’t to be faced when the machine
operates outdoor, but when it’s installed
indoor, the following recommendations must
be followed:
- The chimney path must be always in ascent,
straight vertical if possible, and preferably not
exceeding a 5 m lenght.
- The exit of the chimney must be sheltered to
avoid the dripping of rain and to allow the
exaust flow.
- The chimney section A must be 3 times the outlet
chimney of the machine B and at distance of at
least 20 cm.
It must be underlined that the above
recommendations are extremely important to
prevent the condensate from back dripping
into the machine. The exausts contain
sulphuric acid, condensating at a temperature
of approximately 180° C. The condensation
shall be avoid, but in any case the condensate
from chimney shall not enter the machine.
The non observance of these recommendations
may lead to the damage of the machine.
CHIMNEY SECTION: 3 times the area of chimney
Chimney pipe diameter = 150 mm.
CHIMNEY SECTION FOR 2 BOILER: 6 times the area
of chimney.
Chimney pipe diameter = 225 mm.
FUELLING
Information on the type of diesel fuel to be
used:
Diesel for transport uses and without addi-
tives.
Fill the tank with the fuel indicated on the tech-
nical data plate (Diesel) (see fig.
G)
In order not to damage the fuel pump, ensure
that the tank never empties while running.
WARNING: Use of unsuitable fuel may
result in dangerous situations.
DETERGENT
(see fig.
B)
Fill the detergent tank with the product re-
commended for the task to be carried out.
WARNING: Make use only of liquid
detergent, do not absolutely use acid or too
much alkaline products. We suggest you to
make use of our products, which have been
studied for the use with washer machines.
Turn the master switch to “0” .
• See fig
H
Suction from the high pressure
water cleaner tank: take the cap off (21.) and,
being careful not to spill any of the liquid (we
suggest using a funnel and keeping it for this
purpose), fill the tank (maximum capacity is 3.5
l/0.9 US gal), following the dosage directions
given on the detergent pack; put the cap back
on.
• See fig
J
Suction from an external tank:
remove the cap (31.) and put the fitting (32.) of
the external detergent tank suctioning hose
(33.) in the coupling (30.) (also see Fig. 5); put
the hose (33.) in the external tank containing
the detergent at the strength wanted.
• Turn the detergent regulating knob (28.)
clockwise.
• Turn the knob (28.) until the amount of pro-
duct required is delivered. AftWhen you have
finished using
it, turn the knob (28.) completely anticlockwise
and, if you were using an external tank for suc-
tioning the
detergent, take the fitting (32.) out of the cou-
pling (30.) and put the cap (31.) back on
WATER
see fig.
A)
see section on "WATER SUPPLY"
> 1ST START-UP (BEFORE INITIAL USE)
> Temperature adjustment
EN
21
Summary of Contents for DSG-6 DP
Page 2: ...H2O H2O 1 15 11 18 17 16 3 2 4 6 10 12 13 14 5 7 8 9 A F C D E 2...
Page 3: ...20 19 21 22 23 25 24 26 27 B G 3...
Page 5: ...K 5 min 120 A 3B A B min 20 cm min 7 9 inch...
Page 61: ...06 30 07 08 12 13 14 16 17 18 19 20 XX XY XJ K1 0 K2 K3 K4 RU 61...
Page 62: ...K5 K6 K7 K8 K9 K10 V11 V12 K13 V14 V15 K16 K17 K18 K19 K20 H RU 62...
Page 66: ...B 23 C 0 OFF 1 2 2 1 24 0 OFF 2 0 1 BAR C OFF V15 180 C RU 66...
Page 67: ...OFF K1 K2 DM 329 04 11 1 2 12 9 8 34 20 19 22 A 1 RU 67...
Page 68: ...2 3 4 5 6 7 8 9 2012 19 EU 2012 19 EU 11 8 34 20 RU 68...
Page 80: ...80...