UP
13.
14. 15.
3. 4. 5.
6.
9.
10.
11.
12.
8.
1.
7.
16.
17.
2.
1
2
1.
Indicator LEDs
call sent (green) / system busy (red)
lock-release enabled
communication enabled
2.
Loudspeakers
3.
Speaker volume control
4. S1
Button programming selector
5. S2
Special programming selector
6.
Micro USB input for programming via computer
7.
Jumper for power supply management (remove in case of
separate power supply)
8.
Twilight sensor
9.
Addressing and programming Dip Switches
10.
Microphone volume control
11.
Programming confirmation button
12.
Digital microphone
Use screwdriver supplied
13.
Terminal block for connection:
RTE
programmable RTE (local lock-release
input) or DO input (door open indication)
GND SE-
RTE and door lock input reference
negative
SE+
electric door lock connection
NO NC COM
relay contacts
V- V+
power supply
LL
bus line connection
14.
Ethernet terminal block, only for use in case of additional
modules with LAN
15.
Connector for additional modules with LAN
16. 17.